Need assistance or guidance?

Contact us @: 1-800-301-9097
Login / Register Contact Us
 
CA-LLD-DC100-L500 - Liquids Leak Detection, Water Detection Cable w/o Position, 50m length by ICP DAS

CA-LLD-DC100-L500 - Liquids Leak Detection, Water Detection Cable w/o Position, 50m length
by ICP DAS

Write a review Write a review
CA-LLD-DC100-L500_SUMMARY.html
  • Liquid leak detection
  • Leak detection triggers an audible alarm
  • A mute button to silence the alarm
  • Two LED indicators to display the status of the power and the alarm
  • A configurable relay output
  • Leader cables and sensor cable can be up to 500 meters
  • Adjustable detection sensitivity
  • Supports DCON and Modbus RTU protocols
  • Embedded Dual Watchdog
  • Wide Operating Temperature Range: -25 to +75C
  • Tiny form factor with easy screw mounting (DIN mount versions are available)
Mfg SKU # : CA-LLD-DC100-L500
Our Price : $839.00
Stock : Call for Availability
Quantity :
CA-LLD-DC100-L500_DESCRIPTION.html CA-LLD-DC100-L500 is a low-cost, intelligent liquid leak detection device that can be used to directly control Relay Output. No additional conversion module is needed and the iSN-101 can be easily integrated with a variety of monitoring systems to achieve remote alarm and remote device control. The iSN-101 Liquid Leak Detection module can be used to monitor double-core leader cable, with lengths of up to 500 meters, and can be used with both the sensor cable and its included water leakage probe (S3 modules include probe, otherwise sold separately). If liquid is detected, the controller immediately activates the output relay - the normally open, normally closed passive output signal. The module can be easily integrated with other collection hosts connected to the network. The iSN-101 is suitable for real-time leak detection in critical locations, such as computer room base stations, warehouses, libraries, museums and industrial sites, and also for air handling equipment, refrigeration units, liquid containers, or pump tanks, etc., where there is a need to monitor any leakage of the equipment.
CA-LLD-DC100-L500.html

I/O Specifications

Analog Input
Channels 1
Wiring Cables Length 500 meters (inlcuding sensor cable)
Sound Off button Button used to stop the audible alarm
Adjustment of Detection Sensitivity 25 KO ˜ 580KO

System Specifications

Communication
Interface RS-485
Format N,8,1 / O,8,1 / E,8,1 / N,8,2
Baud Rate Software Configuration: 1200 ˜ 115200 bps
Protocol Modbus RTU or DCON
Node Addresses 96 ˜ 127 for hardware configuration ˜ 255 for software configuration
LED Indicators
LED indicators 1 as Power Indicator, 1 as Alarm Indicator
Relay Output
FORM C Relay 0.5A @ 125 Vac, 2 A @ 30 Vdc
EMS Protection
ESD (IEC 61000-4-2) ±8kV Air for Random Point
EFT (IEC 61000-4-4) ±4kV for Power
Power
Reverse Polarity Protection Yes
Input Voltage Range 10 to 30 Vdc
Consumption 1.5 W max.
Mechanical
Dimensions (W x L x H) 83 mm x 70 mm x 29 mm
Installation DIN-Rail (DIN version modules)or Screw Mounted (standard modules)
Environment
Operating Termperature -25 to +75C
Storage Temperature -30 to +80C
Humidity 10 to 90% RH, non-condensing

Ordering Information

iSN-101 1-channel Liquid Leak Detection Module (ROHS)
iSN-101/DIN 1-channel Liquid Leak Detection Module (DIN-rail mount) (ROHS)
iSN-101/SiSN-101/S/DIN 1 channel Liquid Leak Detection Module (ROHS)Includes an iSN-101 module, a 1m Liquid leak detection cable and 3m extended cable. (DIN or Screw Mount)
iSN-101/S2iSN-101/S2/DIN 1-channel Liquid Leak Detection Module (RoHS)Includes an iSN-101 Module, a 3m Liquid Leak Detection Cable and 3m Extended Cable.(DIN or Screw Mount)
iSN-101/S3iSN-101/S3/DIN 1-channel Liquid Leak Detection Module (RoHS)Includes an iSN-101 Module and a Leakage Probe.(DIN or Screw Mount)
iSN-101/S CR = iSN-101 + CA-LLD-DC100-L010 + CA-LLD-EC-L030 iSN-101/S2 CR = iSN-101 + CA-LLD-DC100-L030 + CA-LLD-EC-L030 iSN-101/S3 CR = iSN-101 + CA-LLD-DP100

l'); ?>
Copyright © 2024 iComTech. All rights reserved. Shopping Cart Software powered by ecMidas.