ZT-2060-IOP - 6 Channel Isolated Digital Inputs and 4 Channel Relay Outputs with pair connection by ICP DAS
|
|
|
Zigbee Wireless 6-channel Isolated Digital Input (Counter) and 4-channel Relay Output (Digital Output) Zigbee Data Acquisition Module. Supports DCON and Modbus RTU Protocols and operating temperatures from -25 ~ +75°C (-13F ~ 167F), Supports I/O Pairing, communication distance up to 700 meters (2297 feet).
|
|
|
The ZT-2060 offers 4 Form A power relay output channels and 6 digital input channels, each of which features photocouple isolation. In addition, you can choose sink-type or source-type input via wire connections. All channels are able to be used as 16-bit counters. The ZT-2060 has 10 LED indicators to display the channel status, and has 4 kV ESD protection and 3000 VDC intramodule isolation. Users can easily configure the module address, protocol, checksum, ZB-PID and ZB-channel settings using a combination of rotary and DIP switches.
- ISM 2.4 GHz Operating Frequency
- Fully Compliant with 2.4G IEEE 802.15.4/ZigBee Specifications
- Wireless Transmission Range up to 700 m
- GUI Configuration Software (Windows Version)
- 6 Digital Input Channels and 4 Relay Output Channels
- Supports 16-bit Counters for Digital Input Channels
- Surge and ESD Protection
- DIN-Rail Mountable
Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote Diagnosis, Testing Equipment. The ZT-2060-IOP supports I/O pairing.
Digital Input |
Input Channels |
6 |
Input Types |
Isolated, Wet Contact (Sink/Source) |
Input Level |
On Voltage Level |
+3.5 VDC ~ +30 VDC |
Off Voltage Level |
+1 VDC Max. |
Input Impedance |
3 kΩ, 0.33 W |
Counter |
Channels |
6 |
Max. Count |
16-bit (65535) |
Max. Input Frequency |
100 Hz |
Min. Pulse Width |
5 ms |
Relay Output |
Output Channels |
4 |
Output Types |
Power Relay, Form A |
Contact Rating |
5 A @ (250 VAC/30 VDC) |
Max. Contact Voltage |
270 VAC/125 VDC |
Operate Time |
10 ms max. at Rated Voltage |
Release Time |
5 ms max. at Rated Voltage |
Endurance |
Electrical |
Resistive Load: 100,000 ops. min. (10 ops/minute) |
Mechanical |
At No Load: 20,000,000 ops. min. (300 ops/minute) |
Dielectric Strength |
Between Contacts |
750 VAC for 1 minute |
Between Coil to Contacts |
3,000 VAC for 1 minute |
Insulation Resistance |
5,080 V (1.2/50 μs) |
Surge Strength |
5 ms max. at Rated Voltage |
ESD Protection |
+/-4 kV contact for each channel |
Communication Interface |
Wireless Standards |
ZigBee 2007 Pro |
Transmission Power |
11 dBm (FCC Certificated) |
2.4 GHz Antenna |
5 dBi Omni directional |
Transmission Range (LoS) |
700 m (Typical) |
Certification |
CE/FCC, FCC ID |
Max. Slaves in a ZigBee Network |
255 |
Protocols |
Supports DCON and Modbus RTU Protocols |
Hot Swap |
Rotary and DIP switch |
LED Indicators |
Power |
1 LED, Red |
ZigBee Communication |
1 LED, Green |
Digital Input and Output |
6 Green LEDs for Digital Input
4 Red LEDs for Relay Output |
Isolation |
Intra-module Isolated,
Field-to-Logic |
2500 VDC |
EMS Protection |
ESD (IEC 61000-4-2) |
4 kV Contact for Power Line, Communication Line
and each Channel, 8 kV Air for Random Point |
EFT (IEC 61000-4-4) |
4 kV for Power Line |
Power |
Input Voltage Range |
+10 VDC ~ +30 VDC |
Power Consumption |
1.4 W Max. |
Mechanical |
Flammability |
Fire Retardant Materials (UL94-V0 Level) |
Dimensions (W x L x H) |
33 mm x 94 mm x 110 mm |
Installation |
DIN-Rail |
Environment |
Operating Temperature |
-25 ~ +75°C |
Storage Temperature |
-30 ~ +80°C |
Relative Humidity |
10 ~ 90% RH, Non-condensing |
|
|