ORing IBS-102FX-SS-LC - Industrial 2-port optical bypass switch for fiber optical network with 4xLC duplex Connector - Single mo by ORing Industrial Networking
|
|
|
|
IBS-102FX-SS-LC
- Support 100M/1G/10G optical bypass function of 2 port duplex or 4 port
simplex fiber connection
- Single-mode optical fiber
- Low insertions loss
- Throughput not affected and no extra delay
- Bypass switching time < 10ms
- Dual wide-range power inputs: 12~48VD
- Relay output for power failure warning
- Rigid IP-30 housing design
- DIN-Rail/Wall-mount installation
|
|
|
IBS-102FX series are the external Bypass switches for 100M/1G/10G fiber
optical networks. These fiber optical bypass switches protect the network from
failures and subsequent maintenance by ensuring network integrity during power
loss. Each of these fiber optical bypass switches includes Network ports and
Monitor ports. The Network ports are used for connection to main-network
connections and provide protection mechanism, and the Monitor ports are used for
down-link local networking device. When the power is on, the operation mode of
the Bypass switch is set to Normal, and the local networking device is connected
with main-network. When power failure occurs, the Bypass switch is swiftly set
to bypass mode to isolate the main-network from the local networking device.
| Physical Ports |
|
|
| LC connector |
4 Duplex Single-mode LC connector |
|
| Fiber Ethernet |
|
|
| Optical Fiber |
Single-mode: 9/125μm |
|
| Operating Wavelength |
1260 ~ 1570 nm |
|
| Insert loss |
typical1.2 dB , Maximun 1.6 dB |
|
| Switch time |
< 10ms |
|
| DIP Switch Settings |
|
|
| DIP Swicth No.1 |
Power-1 failed warning detection – (On) relay enable
(Off) relay disable |
| DIP Swicth No.2 |
Power-2 failed warning detection – (On) relay enable
(Off) relay disable |
| LED Indicators |
|
|
| Power Indicator |
Green : Power LED x 2 |
| Normal indicator |
Green On : Operated in normal mode |
| Fault indicator |
Amber : Indicates power failure occurred |
| Fault contact |
|
|
| Relay |
Relay output for power failure warning |
| Power |
|
|
| Redundant Input Power |
Dual 12~48 VDC power inputs at DC-Jack and 4-pin
terminal block |
| Power Consumption (Typ.) |
2.7 watts |
| Overload Current Protection |
Present |
| Reverse Polarity Protection |
Present on terminal block |
| Physical Characteristics |
|
|
| Enclosure |
IP-30 |
| Dimensions (W x D x H) |
26.1(W) x 94.9(D) x 144.3(H) mm (1.03 x 3.74 x 5.68
inch.) |
| Weight (g) |
405 g |
| Environmental |
|
|
| Storage Temperature |
-40 to 85°C (-40 to 185°F) |
| Operating Temperature |
-40 to 70°C (-40 to 158°F) |
| Operating Humidity |
5% to 95% Non-condensing |
|
| Regulatory Approvals |
|
|
| EMI |
FCC Part 15, CISPR (EN55022) class A, |
| EMS |
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT),
EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 |
| Shock |
IEC60068-2-27 |
| Free Fall |
IEC60068-2-32 |
| Vibration |
IEC60068-2-6 |
| Safety |
EN60950-1 |
| Warranty |
5 years |
|
|
|
|