ICF-1280I-S-ST - Industrial PROFIBUS to Fiber Optic Converter, Single-mode, ST connector, 0 to 60  Degree C by MOXA

ICF-1280I-S-ST - Industrial PROFIBUS to Fiber Optic Converter, Single-mode, ST connector, 0 to 60 Degree C
by MOXA

Write a review Write a review
  • Redundant fiber ring with zero recovery time
  • Examine network-wide fiber communication from a single converter
  • Auto baudrate detection and data speed up to 12 Mbps
  • PROFIBUS bus fail prevents corrupted datagram in functioning segment
  • Alarm by relay output
  • 2 kV galvanic isolation protection
  • Dual power inputs for redundancy
  • Extends PROFIBUS transmission distance up to 45 km
  • Wide temperature model available for -40 to 75°C environments
  • Supports Fiber Signal Intensity Diagnosis
  •  

    Mfg SKU # : ICF-1280I-S-ST
    Our Price : $1,685.52
    Stock : Call for Availability
    Quantity :

    Overview

    The ICF-1280I series industrial PROFIBUS-to-fiber converters are used to convert PROFIBUS signals from copper to optical fiber. The converters are used to extend serial transmission up to 4 km (multi-mode fiber) or up to 45 km (single-mode fiber). The ICF-1280I provides 2 kV isolation protection for the PROFIBUS system and dual power inputs to ensure that your PROFIBUS device will perform uninterrupted.

     

    Remote Fiber Diagnosis

    Optical fiber cables are often deployed for long distance communication and a fiber optic inspection pen is used by engineers to ensure proper communication quality of the fiber cable. The ICF-1280I series converters eliminate the need for a fiber optic inspection pen by providing a Remote Fiber Diagnosis function that uses DIP switch adjustments. There are two major functions provided by Remote Fiber Diagnosis: (1) determining which side (Tx or Rx) is causing the problem on the converter; (2) examining the fiber connections for the overall topology from any individual converter. Fiber cable abnormalities can be automatically detected and identified by the LED indicator even if it is not adjacent to the converter. Remote Fiber Diagnosis facilitates fiber cable deployment and management, and also significantly shortens troubleshooting time by examining fiber connections for the overall topology from any individual converter. 

     

    Redundant Ring

    The ICF-1280I series converters can connect PROFIBUS devices in a redundant fiber ring topology. Use the DIP switch to configure all the ICF- 1280I converters to Redundant Ring mode. When a PROFIBUS master transmits a signal from one converter to the PROFIBUS slave devices, this signal will travel to all the converters around the ring until it returns to the original converter and terminate. The redundant ring structure ensures no packet loss with zero recovery time.

     

    PROFIBUS Fail Safe

    Electrical noise may be generated when a PROFIBUS device malfunctions or the serial interface fails, resulting in bus failure. Traditional media converters transmit noise signals through the fiber wire to the other converter. This not only disrupts data communication between the two buses, but will also bring communication across the entire system to a halt. When this occurs, the engineers will not be able to easily locate the failed device because the entire PROFIBUS network is down. To avoid this situation, the ICF-1280I series converter has a mechanism to detect and recognize noise signals. If the bus fails on one side, the noise signal will not propagate through the ICF-1280I converter and affect additional bus segments. In addition, the ICF-1280I converter will also trigger an alarm to provide the location of the failure to the field engineer.

     

    Fiber Signal Intensity Diagnosis

    In some circumstances, you may need to measure the receive level of the fiber optic port with a voltmeter, which can be connected while the device is operating (doing so will not affect data transmission). The measurement can be taken with a voltmeter and read on a PLC that uses floating high impedance analog inputs, which allows you to do the following: 1. Record the incoming optical power for later measurement (e.g., to indicate aging or damage). 2. Carry out a good/bad test (limit value).

     Technology
    Standards IEC 61158-2 for PROFIBUS DP
     Interface
    P1/P2 Port ST optical fiber
    P3 Port PROFIBUS DP (DB9 female)
    Relay Alarm One relay output with current carrying capacity of 2 A @ 30 VDC (Normal open)
    LED Indicators PWR1, PWR2, Ready, P1, P2, P3, Fault
    DIP Switches DIP 1 to 4: Baudrate setting
    DIP 5: Fiber link monitor
    DIP 6 to 7: Linear/Star mode (w/ optional P1/P2 disable), Redundant Ring mode
    DIP 8: Remote Fiber Diagnosis
     PROFIBUS Communication
    Data Rate 9.6, 19.2, 45.45, 93.75, 187.5, 500, 1500, 3000, 6000, and 12000 Kbps
    Auto Baudrate Yes
    Isolation Protection 2 kV
     Optical Fiber Side
    Point-to-Point, Linear (Bus), Star, Redundant Topologies:
     Physical Characteristics
    Housing Metal
    Mounting DIN-Rail mounting, wall mounting (with optional kit)
    Dimensions 39 x 115 x 70 mm (1.54 x 4.53 x 2.76 in)
    Weight 225 g
     Environmental Limits
    Operating Temperature Standard Models: 0 to 60°C (32 to 140°F)
    Wide Temp. Models: -40 to 75°C (-40 to 167°F)
    Storage Temperature -40 to 75°C (-40 to 167°F)
    Ambient Relative Humidity 5 to 95% (non-condensing)
     Power Requirements
    Input Voltage 12 to 48 VDC
    Power Consumption 315 mA @ 12 V
    Connector Terminal Block
    Power Line Protection Level 3 (2 kV) Surge Protection
    Over Current Protection 1.1 A
     Standards and Certifications
    Safety UL 508, EN 60950-1
    Hazardous Location UL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2 EEx nC IIC, IECEx
    EMC CE, FCC Part 15 Subpart B Class A
    EMI EN 55022, Class A; EN 55024
    EMS EN 61000-4-2 (ESD) Level 3,
    EN 61000-4-3 (RS) Level 3,
    EN 61000-4-4 (EFT) Level 3,
    EN 61000-4-5 (Power Surge) Level 3,
    EN 61000-4-5 (Communication Surge) Level 3,
    EN 61000-4-6 (CS) Level 3
    Green Product RoHS, CRoHS, WEEE
    Freefall IEC 60068-2-32