| • Data Line Surge Protection |
| Maximum Power Protection |
400 watts |
| Number of Protected Lines |
ISD-1110-T: 7
ISD-1130-T: 4 |
| Surge Capacity |
4 kV, 8/20 μs impulse per line |
| Working Voltage |
ISD-1110-T: 15 V
ISD-1130-T: 5 V |
| Maximum Load Current |
ISD-1110-T: 0.1 A (23°C), 0.05 A (85°C)
ISD-1130-T: 0.12 A (23°C), 0.07 A (85°C) |
| Response Time |
< 1 ns |
| Protection Mode |
Line to line, line to ground |
| Protection Rating |
IP30 |
| Bandwidth |
10 MHz loss < 1 dB |
| • Connectors |
| ISD-1110-T |
Data in: DB9 male
Data out: DB9 female |
| ISD-1130-T |
Data in: Terminal block
Data out: Terminal block |
| • Physical Characteristics |
| Housing |
Plastic |
| Weight |
Product only
ISD-1110-T: 58 g
ISD-1130-T: 30 g
Packaged
ISD-1110-T: 119 g
ISD-1130-T: 96 g |
| Dimensions |
ISD-1110-T: 53 x 37 x 20.6 mm (2.01 x 1.46 x 0.81 in)
ISD-1130-T: 53 x 37 x 20.6 mm (2.01 x 1.46 x 0.81 in) |
| • Environmental Limits |
| Operating Temperature |
-40 to 85°C (-40 to 185°F) |
| Storage Temperature |
-40 to 85°C (-40 to 185°F) |
| Ambient Relative Humidity |
95% max, non-condensing |
| Altitude |
Up to 2000 m |
| Note |
Please contact Moxa if you require products guaranteed to function properly at higher altitudes. |
| • Standards and Certifications |
| EMS |
EN 61000-4-5 Level 4 (4 kV)) |
| • Warranty and RMA Policy |
| Warranty Period |
5 years (limited to 1-time use) |
| Warranty Details |
See www.moxa.com/warranty |
| Note |
ISD products will only be repaired once within 5 years of purchase. After the first repair, the product’s warranty will no longer be valid. |
| RMA Policy |
Moxa does not provide RMA service for ISD products whose PCB board was destroyed by a surge. |
| Note |
Be sure to purchase the ISD product with maximum surge protection suitable for your environment. |