AC Hardware |
IOLAN SDS16C |
Processor |
MPC8349E, 400 Mhz, 750 MIPS |
Memory |
RAM MB |
64 |
Flash MB |
16 |
Interface Ports |
Number of Serial Ports |
16 |
Serial port interface |
Software selectable RS232 / RS485 / RS422 DTE on RJ45 - RS485: full and half duplex |
Sun / Solaris |
Sun / Oracle ‘Solaris' Safe - no "break signal" sent during
power cycle causing costly server re-boots or downtime |
Serial port speeds |
50bps to 230Kbps with customizable baud rate support |
Data bits |
5,6,7,8, 9-bit protocol support |
Parity |
Odd, even, Mark, Space, None |
Flow Control |
Hardware, Software, Both, None |
Serial port protection |
15Kv Electrostatic Discharge Protection (ESD) |
Local console port |
RS232 on RJ45 with DB9 adapter ( provided ) |
Network |
Dual 10/100/1000-base TX ethernet RJ45 |
Software selectable Ethernet speed 10/100/1000, Auto |
Software selectable Half/Full/Auto duplex |
Power |
Power Supply |
USA - IEC320-C13 to NEMA 5-15P line cord
|
Nominal Input Voltage |
110/230v AC |
Input Voltage Range |
100-240v AC |
AC Input Frequency: |
47-63Hz |
Typical power consumption
( Watts ) |
15.0 |
Indicators |
LEDs |
Power |
System Ready |
Network Link activity for each ethernet port |
Serial: Transmit and Receive data per port |
Environmental Specifications |
Heat Output
( BTU/HR ) |
51.18 |
MTBF( hours *) |
106,970 |
Operating Temperature: |
0C to 55C, 32F to 131F |
Storage Temperature: |
-40C to 85C, -40F to 185F |
Humidity: |
5 to 95% (non condensing) for both storage and operation |
Case |
SECC Zinc plated sheet metal (1 mm) |
Ingress Protection rating: |
IP30 |
Mounting |
1U - 19" rack, front and rear mounting hardware included. DIN Rail mounting kit optional |
Product Weight and Dimensions |
Weight |
3.1 Kg, 6.8 lbs |
Dimensions |
1U Rack form factor - 26.4 x 43.4 x 4.4 (cm), 10.38 x 17.1 x 1.75 (in) |
Packaging |
Shipping Dimensions: |
59 x 36 x 9 (cm), 23 x 14 x 3.5 (in) |
Shipping weight: |
4.3 Kg, 9.5 lbs |
Regulatory Approvals |
Emissions: |
FCC Part 15, Subpart B, Class A |
CFR47:2003, Chapter 1, Part 15 Subpart B,(USA) Class A |
ICES-003, Issue 4, February 2004 (Canada) |
EN55022:1998 + A1:2000 + A2:2003 Class A |
EN61000-3-2 : 1995, Limits for Harmonic Current Emissions |
EN61000-3-3 : 1995, Limits of Voltage Fluctuations and Flicker |
Immunity |
EN55024:1998 + A1:2001 + A2:2003 |
EN61000-4-2: Electrostatic Discharge |
EN61000-4-3: RF Electromagnetic Field Modulated |
EN61000-4-4: Fast Transients |
EN61000-4-5: Surge |
EN61000-4-6: RF Continuous Conducted |
EN61000-4-8: Power-Frequency Magnetic Field |
EN61000-4-11: Voltage Dips and Voltage Interruptions |
Standard Safety Certifications: |
IEC 60950-1 : 2005 (2nd Edition) + A1 : 2009 and
EN 60950-1 : 2006 + A11 : 2009 |
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1, First Edition April 1st 2003 (Recognized Component) |
Other: |
Reach, RoHS and WEEE Compliant |
CCATS - G052929 |
ECCN - 5A992A |
HTSUS Number: 8471.80.1000 |
Perle Limited Lifetime Warranty |
IOLAN DTE
RJ45 Socket |
IOLAN RJ45 Socket |
Direction |
RS232 |
RS422 |
RS485 Full Duplex |
RS485 Half Duplex |
1 |
|
RTS |
TXD+ |
TXD+ |
Data+ |
2 |
|
DTR |
|
|
|
3 |
|
TXD |
TXD- |
TXD- |
Data- |
4 |
--- |
GND |
GND |
GND |
GND |
5 |
--- |
GND |
GND |
GND |
GND |
6 |
|
RXD |
RXD+ |
RXD+ |
|
7 |
|
DSR |
|
|
|
8 |
|
CTS |
RXD- |
RXD- |
|
A "rolled" CAT5 cable will automatically perform DTE to DCE crossover
|