Need assistance or guidance?

Contact us @: 1-800-301-9097
Login / Register Contact Us
 
MGate 5217I-600-T - 2-port Modbus RTU/ASCII/TCP-to-BACnet/IP gateways by MOXA

MGate 5217I-600-T - 2-port Modbus RTU/ASCII/TCP-to-BACnet/IP gateways
by MOXA

Write a review Write a review
  •  Supports Modbus RTU/ASCII/TCP master/client
  •  Supports BACnet/IP slave/server
  •  Supports 600 points and 1200 points models
  •  Supports COV for fast data communication
  •  Supports virtual nodes designed to make each Modbus device as a separate BACnet/IP device
  •  Configures Modbus commands quickly by editing an Excel spreadsheet
  •  Embedded traffic and diagnostic information for easy troubleshooting
  •  Built-in Ethernet cascading for easy wiring
  •  Industrial design with -40 to 75°C operating temperature range
  •  Serial port with 2 kV isolation protection
  •  Dual AC/DC power supply
  •  Security features based on IEC 62443

 

Mfg SKU # : MGate 5217I-600-T
Our Price : $706.75
Stock : Call for Availability
Quantity :

MGate 5217I-600-T of the MGate 5217I Series comprise 2-port BACnet gateways that can convert Modbus RTU/ACSII/TCP to BACnet/IP protocol. Depending on the size and the scale of the network, the gateways provide 600-point and 1200-point models. All models are rugged, DIN-rail mountable, operate in wide temperatures, and offer built-in 2kV isolation for serial signals.

Easy Configuration Via Web Console and Excel Spreadsheet

The MGate 5217I Series comes with an intuitive UI design to make configuration easy. With that, you can easily access protocol conversion modes and finish the configuration in a few steps instead of installing an additional engineering utility in your computer. Besides, the MGate can generate Modbus commands by importing an Excel spreadsheet, which makes it easy to edit Modbus commands.

Modbus and BACnet/IP Protocol Traffic Monitor and Diagnostics

The MGate 5217I gateways support Modbus and BACnet/IP Protocol Traffic Monitor and Diagnostics for easy troubleshooting, especially during the installation stage. Communication issues could be caused by incorrect software parameters, such as the wrong slave ID and register address, or an incorrect command configuration. With Diagnostics, you can check the communication status and view values at a glance. With Modbus/BACnet Protocol Traffic Monitor, you can check the captured data and easily identify the root cause.

Security Features Based on IEC 62443

Using network devices that are IEC 62443-4-2 compliant and equipped with basic security capabilities is an effective precautionary measure to ward off cyberattacks. The MGate 5217I Series is capable of several basic security capabilities, including password cracking defense, sniffer and data breach prevention, whitelisting, and the account management.

Ethernet Interface

  • 10/100BaseT(X) Ports (RJ45 connector)

    2
    Auto MDI/MDI-X connection

  • Magnetic Isolation Protection

    1.5 kV (built-in)

Ethernet Software Features

  • Industrial Protocols

    Modbus TCP Client (Master), BACnet/IP Server (Slave)

  • Configuration Options

    Web Console (HTTP/HTTPS), Device Search Utility (DSU), Telnet Console

  • Management

    ARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3, TCP/IP, Telnet, UDP, NTP Client

  • MIB

    RFC1213, RFC1317

  • Time Management

    NTP Client

Serial Interface

  • No. of Ports

    2

  • Connector

    DB9 male

  • Serial Standards

    RS-232/422/485

  • Baudrate

    50 bps to 921.6 kbps

  • Data Bits

    7, 8

  • Parity

    None, Even, Odd, Space, Mark

  • Stop Bits

    1, 2

  • Flow Control

    RTS Toggle (RS-232 only), RTS/CTS, DTR/DSR

  • RS-485 Data Direction Control

    ADDC® (automatic data direction control)

  • Pull High/Low Resistor for RS-485

    1 kilo-ohm, 150 kilo-ohms

  • Terminator for RS-485

    120 ohms

  • Isolation

    2 kV (built-in)

Serial Signals

  • RS-232

    TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

  • RS-422

    Tx+, Tx-, Rx+, Rx-, GND

  • RS-485-2w

    Data+, Data-, GND

  • RS-485-4w

    Tx+, Tx-, Rx+, Rx-, GND

Serial Software Features

  • Industrial Protocols

    Modbus RTU/ASCII Master

Modbus RTU/ASCII

  • Mode

    Master

  • Functions Supported

    1, 2, 3, 4, 5, 6, 16

  • Max. No. of Commands

    MGate 5217I-600-T: 600 (up to 300 commands/per serial port)
    MGate 5217I-1200-T: 1200 (up to 600 commands/per serial port)

Modbus TCP

  • Mode

    Client (Master)

  • Functions Supported

    1, 2, 3, 4, 5, 6, 16

  • Max. No. of Server Connections

    32

  • Max. No. of Commands

    MGate 5217I-600-T: 600
    MGate 5217I-1200-T: 1200

BACnet/IP

  • Mode

    Server (Slave)

  • Memory Size

    MGate 5217I-600-T: 600 points
    MGate 5217I-1200-T: 1200 points

  • Supported BACnet Object

    Binary Input
    Binary Output
    Binary Value
    Analog Input
    Analog Output
    Analog Value
    Multi-state Input
    Multi-state Output
    Multi-state Value
    Integer Value
    Positive Integer Value

Power Parameters

  • Input Voltage

    24 VAC, 12 to 48 VDC

  • Input Current

    300 mA @ 24 VAC
    510 mA @ 12 VDC

  • Power Connector

    Screw-fastened Euroblock terminal

Relays

  • Contact Current Rating

    Resistive load: 1 A @ 30 VDC

Physical Characteristics

  • Housing

    Plastic

  • IP Rating

    IP30

  • Dimensions (without ears)

    29 x 89.2 x 118.5 mm (1.14 x 3.51 x 4.67 in)

  • Dimensions (with ears)

    29 x 89.2 x 124.5 mm (1.14 x 3.51 x 4.90 in)

  • Weight

    380 g (0.84 lb)

Environmental Limits

  • Operating Temperature

    -40 to 75°C (-40 to 167°F)

  • Storage Temperature (package included)

    -40 to 85°C (-40 to 185°F)

  • Ambient Relative Humidity

    5 to 95% (non-condensing)

Standards and Certifications

  • EMC

    EN 55032/35

  • EMI

    CISPR 32, FCC Part 15B Class A

  • EMS

    IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
    IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
    IEC 61000-4-5 Surge: Power: 2 kV
    IEC 61000-4-6 CS: 10 V
    IEC 61000-4-8 PFMF
    IEC 61000-4-11 DIPs

  • Safety

    UL 62368-1, IEC 62368-1

  • Freefall

    IEC 60068-2-32

  • Shock

    IEC 60068-2-27

  • Vibration

    IEC 60068-2-6, IEC 60068-2-64

MTBF

  • Time

    1,277,500 hrs

  • Standards

    Telcordia SR332


Copyright © 2024 iComTech. All rights reserved. Shopping Cart Software powered by ecMidas.