Moxa’s new CB-602I CAN (Controller Area Network) interface board supports the PC/104-Plus interface. Optional DB9 and DB25 connection cables are available for connecting to CAN interface device. The CB-602I CAN interface board uses the NXP SJA1000 and transceiver PCA82C251, which provide the bus arbitration and error detection. The -40 to 85°C wide operating temperature (CB-602I-T only) and 2 kV isolation make the boards suitable for use in harsh industrial environments.
| • Hardware |
| Connector |
20-pin box header |
| CAN Controller |
NXP SJA1000 |
| CAN Transceiver |
PCA82C251 |
| CAN Specification |
CAN 2.0 A/B |
| Signal Support |
CAN_H, CAN_L, GND |
| Transfer Rate |
1 Mbps |
| Max. Number of Boards per PC |
4 |
| Electrical Isolation |
2 kV |
| Termination Resistor |
120 ohms (selected by jumper) |
| • Driver Support |
| Operating Systems |
Windows 2000, Windows XP/2003/Vista/2008 (x86/x64) |
| Linux Real TTY Drivers |
Linux 2.6.x, 3.x |
| Note |
Please refer to Moxa’s website for the latest driver support information. |
| • Software |
| Libraries |
Visual C/C++, Borland C/C++ |
| • Environmental Limits |
| Operating Temperature |
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F) |
| Storage Temperature |
-40 to 85°C (-40 to 185°F) |
| Ambient Relative Humidity |
5 to 95% (non-condensing) |
| Altitude |
Up to 2000 m |
| Note |
Please contact Moxa if you require products guaranteed to function properly at higher altitudes. |
| • Standards and Certifications |
| EMC |
CE, FCC |
| EMI |
EN 61000-3-3, FCC Part 15 Subpart B Class B |
| EMS |
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 (DIPS) |
| Green Product |
RoHS, CRoHS, WEEE |
| • MTBF (mean time between failures) |
| Time |
248,563 hrs |
| Database |
Telcordia (Bellcore), GB |
| • Power Requirements |
| Power Consumption |
380 mA @ 5 VDC |
|