  • 24V DC Output Voltage
  • 3.75 Amps
  • 90 Watts
  • Dual-phase AC Input
  • Input Voltage Range: 264 to 575 V AC

 

Mfg SKU # : 29043718
List Price : $145.00
Our Price : $131.00
Stock : 5
Quantity :

29043718 UNO-PS/2AC/24DC/90W/C2LPS Power Supply of the UNO-PS/2AC/24DC/90W/C2LPS Industrial Power Supply is a rugged 2-Phase AC to DC Converter built to meet the high stability and efficiency expectations of industrial, machine automation and process control environments. This Switching (switch mode) Power Supply ensures a regulated output voltage even in the event of voltage fluctuations in the power supply network. With all required safety certifications to support ITE (Information Technology Equipment), ruggedized packaging, extended operating temperature, high peak load capabilities and high isolation voltage, the UNO-PS/2AC Industrial Power Supply is designed to meet the needs of your 2-Phase power industrial application for loads up to 90 W.

Industrial operating temperature of -25°C to +70°C

Equipment found in traffic management, oil and gas pipelines, weather tracking, industrial and outdoor applications must function in temperatures that cannot be supported by a commercial power supplies. With an operating temperature of -25°C to +70°C, the UNO-PS/2AC Industrial Power Supply is ideal for use with equipment subjected to harsh environments and severe temperatures.

High efficiency up to 89% and low no load power consumption

Compared with other products on the market, the UNO 2-Phase Industrial Power Supply provides excellent energy savings. With a very low no load power consumption and 89% efficiency at nominal load, just a small amount of electrical energy is converted into undesired heat energy making this a very ECO friendly power supply.

Ideal application environments for the UNO 2-Phase DIN Rail Power Supply

  • buildings wired for two-phase distribution systems
  • AC Servo Motors
  • automated production process
  • industrial control, automation, assembly, and test equipment
  • building control, security and surveillance, and climate control systems.
  • power countless industrial automation devices such as sensors, controllers and valves

Other reasons to choose the UNO -PS/2AC Industrial Power Supply

  • 55 mm wide DIN Rail mount narrow housing
  • Voltage Isolation input/output: 4 kV AC
  • LED indicator for voltage out failure: If the output voltage is below the operational range, the LED turns off.
  • Protections: Short-circuit, Overload, Over voltage, Over-temperature
  • High MTBF (Mean Time Between Failure) values ensure maximum availability
  • IEC Protection Class II Power Supplies

Industrial Class 2 Power Supply

With the NEC designation as a Class 2 Power Supply, all regulations address the wiring requirements (wire size and insulation, wire derating factors, overcurrent protection limits and methods of wiring installation) between the output of the supply and the input of the load are met by the UNO-PS/2AC. The output voltage and power delivery capabilities of this Class 2 power supply will lower the risk of fire initiation and electrical shocks, which allows for lower cost wiring methods to be employed when installing an electrical system in a building.

Environmental Product Compliance
REACH SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 25;
General
Net weight 0.32 kg
Efficiency typ. 89 % (400 V AC)
typ. 89 % (480 V AC)
Insulation voltage input/output 4 kV AC (type test)
3 kV AC (routine test)
Protection class II (in closed control cabinet)
Degree of protection IP20
MTBF (IEC 61709, SN 29500) 828172 h (40 °C)
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions alignable: 0 mm horizontally, 30 mm vertically
Standards and Regulations
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Noise immunity EN 61000-6-2:2005
Connection in acc. with standard CUL
Standards/regulations EN 61000-4-2
Contact discharge 4 kV (Test Level 2)
Standards/regulations EN 61000-4-3
Frequency range 80 MHz ... 1 GHz
Test field strength 10 V/m
Frequency range 1.4 GHz ... 2 GHz
Test field strength 3 V/m
Standards/regulations EN 61000-4-4
Comments Criterion B
Standards/regulations EN 61000-6-3
EN 61000-4-6
Frequency range 10 kHz ... 80 MHz
Voltage 10 V (Test Level 3)
Standards/regulations EN 61000-4-11
Low Voltage Directive Conformance with LV directive 2006/95/EC
Standard - Safety of transformers EN 61558-2-16
Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolation DIN VDE 0100-410
Standard – Limitation of mains harmonic currents EN 61000-3-2
UL approvals UL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
NEC Class 2 as per UL 1310
UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Approval - requirement of the semiconductor industry with regard to mains voltage dips EN 61000-4-11
Information technology equipment - safety (CB scheme) CB Scheme
Connection data, input
Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 14
Stripping length 8 mm
Screw thread M3
Output data
Nominal output voltage 24 V DC ±1 %
Nominal output current (IN) 3.75 A
3.38 A (Derating 10 %)
Derating 55 °C ... 70 °C (2.5%/K)
Connection in parallel no
Connection in series No
Feedback resistance < 35 V DC
Protection against surge voltage on the output ≤ 35 V DC
Control deviation < 1 % (change in load, static 10 % ... 90 %)
< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Residual ripple < 50 mVPP (with nominal values)
Output power 90 W
Maximum power dissipation in no-load condition < 0.7 W
Power loss nominal load max. < 12 W
Dimensions
Width 55 mm
Height 90 mm
Depth 84 mm
Weight per piece 352.5 GRM
Input data
Nominal input voltage range 2x 400 V AC ... 500 V AC
Input voltage range 2x 264 V AC ... 575 V AC
Current consumption 0.55 A (400 V AC)
0.48 A (500 V AC)
Nominal power consumption 211.3 VA
Inrush surge current < 30 A (typical)
Mains buffering typ. 65 ms (400 V AC)
typ. 100 ms (500 V AC)
Input fuse 2 A (slow-blow, internal)
Choice of suitable circuit breakers 6 A ... 16 A (Characteristics B, C, D, K)
Power factor (cos phi) 0.48
Type of protection Transient surge protection
Protective circuit/component Varistor
Connection data, onput
Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 14
Stripping length 8 mm
Screw thread M3
Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2
Approvals
 
  • UL Recognized
  • cUL Recognized
  • cUL Listed
  • UL Listed
  • IECEE CB Scheme