| Environmental Product Compliance |
| REACH SVHC |
Lead 7439-92-1 |
| China RoHS |
Environmentally Friendly Use Period = 25; |
| General |
| Net weight |
0.27 kg |
| Operating voltage display |
Green LED |
| Efficiency |
> 86 % (for 230 V AC and nominal values) |
| Insulation voltage input/output |
4 kV AC (type test) |
|
3.75 kV AC (routine test) |
| Insulation voltage input / PE |
3.5 kV AC (type test) |
|
2 kV AC (routine test) |
| Insulation voltage output / PE |
500 V DC (routine test) |
| Protection class |
II (in closed control cabinet) |
| Degree of protection |
IP20 |
| MTBF (IEC 61709, SN 29500) |
|
|
> 1061000 h (40 °C) |
| Mounting position |
horizontal DIN rail NS 35, EN 60715 |
| Assembly instructions |
alignable: 0 mm horizontally, 30 mm vertically |
| Standards and Regulations |
| Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
| Noise immunity |
EN 61000-6-2:2005 |
| Connection in acc. with standard |
CUL |
| Standards/regulations |
EN 61000-4-2 |
| Contact discharge |
4 kV (Test Level 2) |
| Standards/regulations |
EN 61000-4-3 |
| Frequency range |
80 MHz ... 1 GHz |
| Test field strength |
10 V/m |
| Frequency range |
1.4 GHz ... 2 GHz |
| Test field strength |
3 V/m |
| Standards/regulations |
EN 61000-4-4 |
| Comments |
Criterion B |
| Standards/regulations |
EN 61000-6-3 |
|
EN 61000-4-6 |
| Frequency range |
10 kHz ... 80 MHz |
| Voltage |
10 V (Test Level 3) |
| Standards/regulations |
EN 61000-4-11 |
| Low Voltage Directive |
Conformance with LV directive 2006/95/EC |
| Standard - Safety of transformers |
EN 61558-2-16 |
| Standard - Electrical safety |
IEC 60950-1/VDE 0805 (SELV) |
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations |
EN 50178/VDE 0160 (PELV) |
| Standard – Safety extra-low voltage |
IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
| Standard - Safe isolation |
DIN VDE 0100-410 |
| Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment |
EN 50178 |
| Standard – Limitation of mains harmonic currents |
EN 61000-3-2 |
| Shipbuilding approval |
DNV GL (EMC B), ABS, LR, RINA, NK, BV |
| UL approvals |
UL/C-UL listed UL 508 |
|
UL/C-UL Recognized UL 60950-1 |
|
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T3C (Hazardous Location) |
|
NEC Class 2 as per UL 1310 |
| Shock |
18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| Vibration (operation) |
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
|
15 Hz ... 150 Hz, 2.3g, 90 min. |
| Information technology equipment - safety (CB scheme) |
CB Scheme |
| Rail applications |
EN 50121-4 |
| Connection data, input |
| Connection method |
Screw connection |
| Conductor cross section solid min. |
0.2 mm² |
| Conductor cross section solid max. |
2.5 mm² |
| Conductor cross section flexible min. |
0.2 mm² |
| Conductor cross section flexible max. |
2.5 mm² |
| Conductor cross section AWG min. |
24 |
| Conductor cross section AWG max. |
12 |
| Stripping length |
6.5 mm |
| Screw thread |
M3 |
| Output data |
| Nominal output voltage |
24 V DC ±1 % |
| Setting range of the output voltage (USet) |
22.5 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted) |
| Nominal output current (IN) |
2.5 A (-25 °C ... 55 °C) |
|
2.75 A (-25°C ... 40°C permanent ) |
| Output current Imax |
4.4 A |
| Derating |
55 °C ... 70 °C (2.5%/K) |
| Connection in parallel |
Yes, for redundancy and increased capacity |
| Connection in series |
yes |
| Feedback resistance |
≤ 35 V DC |
| Protection against surge voltage on the output |
≤ 35 V DC |
| Control deviation |
< 1 % (change in load, static 10 % ... 90 %) |
|
< 2 % (change in load, dynamic 10 % ... 90 %) |
|
< 0.1 % (change in input voltage ±10 %) |
| Residual ripple |
< 80 mVPP (20 MHz) |
| Output power |
60 W |
| Typical response time |
< 0.5 s |
| Peak switching voltages nominal load |
< 40 mVPP (20 MHz) |
| Maximum power dissipation in no-load condition |
< 0.7 W |
| Power loss nominal load max. |
9.9 W |
| Dimensions |
| Width |
72 mm |
| Height |
90 mm |
| Depth |
61 mm |
| Weight per piece |
270.0 GRM |
| Input data |
| Nominal input voltage range |
100 V AC ... 240 V AC |
| Input voltage range |
85 V AC ... 264 V AC |
|
95 V DC ... 250 V DC |
| AC frequency range |
45 Hz ... 65 Hz |
| Frequency range DC |
0 Hz |
| Current consumption |
0.8 A (120 V AC) |
|
0.4 A (230 V AC) |
| Nominal power consumption |
124.3 VA |
| Inrush surge current |
< 15 A (typical) |
| Mains buffering |
typ. 20 ms (120 V AC) |
|
typ. 100 ms (230 V AC) |
| Input fuse |
3.15 A (slow-blow, internal) |
| Choice of suitable circuit breakers |
6 A ... 16 A (Characteristics B, C, D, K) |
| Power factor (cos phi) |
0.56 |
| Type of protection |
Transient surge protection |
| Protective circuit/component |
Varistor |
| Connection data, onput |
| Connection method |
Screw connection |
| Conductor cross section solid min. |
0.2 mm² |
| Conductor cross section solid max. |
2.5 mm² |
| Conductor cross section flexible min. |
0.2 mm² |
| Conductor cross section flexible max. |
2.5 mm² |
| Conductor cross section AWG min. |
24 |
| Conductor cross section AWG max. |
12 |
| Stripping length |
6.5 mm |
| Screw thread |
M3 |
| Ambient conditions |
| Degree of protection |
IP20 |
| Ambient temperature (operation) |
-25 °C ... 70 °C (> 55° C derating : 2.5%/K) |
| Ambient temperature (storage/transport) |
-40 °C ... 85 °C |
| Max. permissible relative humidity (operation) |
≤ 95 % (at 25 °C, non-condensing) |
| Climatic class |
3K3 (in acc. with EN 60721) |
| Degree of pollution |
2 |
| Approvals |
| |
- cULus Listed
- DNV GL
- BV
- BSH
- RINA
- cUL Recognized
- cUL Listed
- LR
- UL Listed
- IECEE CB Scheme
- cULus Listed
- cULus Recognized
- EAC
- UL Recognized
- NK
- ABS
|