Moxa WAC-1001-T - Industrial wireless access controller, -40 to to 75 Degree C by MOXA
|
|
|
- Redundant 12 to 48 VDC power inputs
- Less than 50 ms controller empowered Turbo Roaming
- Supported models: AWK-RTG series
- Compliant with essential sections of EN 50155
- IEEE 802.11i-compliant wireless security
- DIN-rail or wall mounting for onsite installation
- -40 to 75°C operating temperature range (T model)
|
|
|
Introduction
The goal of zero-latency-roaming is to create networks that maintain communications seamlessly as clients move from one access point to another. For this, as a part of the AWK-RTG series, Moxa has introduced the WAC-1001 with Controller-based Turbo Roaming technology, a wireless access controller that can achieve less than 50 ms roaming on three channels.. This advanced roaming capability securely hands off clients at speeds so high that wireless clients may roam between APs almost seamlessly, with virtually no interruption in connectivity. Moreover, the WAC-1001 is suitable for use even in extremely demanding environments, meeting the essential sections of EN 50155 that cover operating temperature, power input voltage, surge, ESD and vibration.
Advanced Security
- Sub-50 ms Turbo Roaming
- Configuration back-up
- Dual redundant DC power inputs
Maximum Availability
- IEEE802.1X/RADIUS supported
- WPA/WPA2/802.11i supported
- Integrated DI/DO for on-site monitoring and warnings
• WLAN Interface |
Standards |
IEEE 802.11i for Wireless Security
IEEE 802.3u for 10/100BaseT(X)
IEEE 802.3af for Power-over-Ethernet |
Security |
WPA /WPA2-Personal and Enterprise (IEEE 802.1X/RADIUS, TKIP, and AES) |
• Interface |
LAN Port |
10/100BaseT(X), auto negotiation speed (RJ45-type) |
Console |
RS-232 (RJ45-type) |
LED Indicators |
PWR1, PWR2, PoE, FAULT, STATE, 10M, 100M |
Alarm Contact |
1 relay output with current carrying capacity of 1 A @ 24 VDC |
Digital Inputs |
2 electrically isolated inputs
• +13 to +30 V for state “1”
• +3 to -30 V for state “0”
• Max. input current: 8 mA |
• Physical Characteristics |
Housing |
Metal, providing IP30 protection |
Weight |
700 g |
Dimensions |
52.85 x 135 x 105 mm (2.08 x 5.31 x 4.13 in) |
Installation |
DIN-Rail mounting, wall mounting |
• Environmental Limits |
Operating Temperature |
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
• Power Requirements |
Input Voltage |
12 to 48 VDC, redundant dual DC power inputs or 48 VDC Power-over-Ethernet (IEEE 802.3af compliant) |
Note |
*Compliant with EN 50155 on 24 VDC |
Connector |
10-pin removable terminal block |
Power Consumption |
12-48 VDC, 0.121-0.494 A (max.)
Maximum 5.6 watts |
Reverse Polarity Protection |
Present |
• Standards and Certifications |
Safety |
UL 60950-1, EN 60950-1 |
EMC |
FCC Part 15 Subpart B Class A, EN 55022/55024 |
Rail Traffic |
EN 50155*, EN 50121-1/4 |
Note |
*Complies with a portion of EN 50155 specifications. Please contact Moxa or a Moxa distributor for details. |
• Reliability |
MTBF (mean time between failures) |
485,432 hrs |
|
|
|
|