						Moxa NE-4100T-P - 10/100M Ethernet Network Enabler for serial(TTL) device, DIL package, with programmable firmware by  MOXA
					 | 
														 
				 |  
								
					| 
						
					 | 
				 
					 
		
  - 10/100 Mbps Ethernet interface
 
  - Up to 230.4 Kbps baudrate support
 
  - Choice of operation modes: Real COM, TCP Server, TCP Client, and UDP
 
  - DHCP, BootP, Static IP, and ARP supported
 
  - SNMP and e-mail alerts for event trapping and notification
 
  - Half the size of a credit card—only 57 × 40 mm
 
  - Low power consumption at 1.5W, with single +5V input
 
 
         | 
       
       |  
     
     | 
   
  
    
	
		
		
Moxa's NE-4100 embedded device servers are designed formanufacturers who want to add sophisticated network connectivityto their serial devices. Moxa's embedded device servers can be usedto convert any device with a standard serial interface to an Ethernet -enableddevice in no time. The NE-4100 embedded device servers support 10/100 Mbps Ethernet, and provide ready-to-use operationmodes, including TCP Server, TCP Client, and UDP. In addition, aReal COM driver is included for backward compatibility with legacysoftware.
 
		
  
    
      | • Form Factor | 
     
    
      | Type | 
      Drop-in module | 
     
    
      | Dimensions | 
      45 × 36 mm (1.77 x 1.42 in) | 
     
    
      | Weight | 
      NE-4110S/4110A: 40 g 
        NE-4120S/4120A/4100T: 20 g | 
     
    
      | • Ethernet Interface | 
     
    
      | Number of Ports | 
      1 | 
     
    
      | Speed | 
      10/100 Mbps, auto MDI/MDIX | 
     
    
      | Magnetic Isolation Protection | 
      1.5 kV built-in | 
     
    
      | Connector | 
      26-pin dual-in-line | 
     
    
      | • Serial Interface | 
     
    
      | Number of Ports | 
      2 | 
     
    
      | Serial Standards | 
      • Port 1:TTL 
        • Port 2:TTL console port | 
     
    
      | RS-485 Data Direction Control | 
      ADDC® (automatic data direction control) | 
     
    
      | • Serial Communication Parameters | 
     
    
      | Data Bits | 
      5, 6, 7, 8 | 
     
    
      | Stop Bits | 
      1, 1.5, 2 | 
     
    
      | Parity | 
      None, Even, Odd, Space, Mark | 
     
    
      | Flow Control | 
      DSR/DTR and RTS/CTS (RS-232 only), XON/XOFF | 
     
    
      | Baudrate | 
      110 bps to 230.4 kbps | 
     
    
      | • Serial Signals | 
     
    
      | TTL | 
      • Port 1: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND 
        • Port 2: TxD, RxD, GND | 
     
    
      | RS-232 | 
      TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND | 
     
    
      | RS-422 | 
      Tx+, Tx-, Rx+, Rx-, GND | 
     
    
      | RS-485-4w | 
      Tx+, Tx-, Rx+, Rx-, GND | 
     
    
      | RS-485-2w | 
      Data+, Data-, GND | 
     
    
      | • Digital I/O Pins | 
     
    
      | GPIO | 
      4 programmable I/O pins | 
     
    
      | • Software | 
     
    
      | Network Protocols | 
      ICMP, ARP, IPv4, TCP, UDP, DHCP, Telnet, HTTP, SNMP V1/V2c, SMTP | 
     
    
      | Configuration Options | 
      Web Console, Serial Console, Telnet Console, Windows Utility | 
     
    
      | Windows Real COM Drivers | 
      Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded | 
     
    
      | Fixed TTY Drivers | 
      SCO Unix, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X | 
     
    
      | Linux Real TTY Drivers | 
      Linux 2.4.x, 2.6.x, 3.x | 
     
    
      | Operation Modes | 
      Real COM, TCP Server, TCP Client, UDP | 
     
    
      | • Environmental Limits | 
     
    
      | Operating Temperature | 
      Standard Models: 0 to 55°C (32 to 131°F) 
        Wide Temp. Models: -40 to 75°C (-40 to 167°F) | 
     
    
      | Storage Temperature | 
      -40 to 60°C (-40 to 140°F) | 
     
    
      | Ambient Relative Humidity | 
      5 to 95% (non-condensing) | 
     
    
      | Altitude | 
      Up to 2000 m | 
     
    
      | Note | 
      Please contact Moxa if you require products guaranteed to function properly at higher altitudes. | 
     
    
      | • Power Requirements | 
     
    
      | Input Voltage | 
      5 VDC (±5%) | 
     
    
      | Power Consumption | 
      290 mA @ 5 VDC max. | 
     
    
      | • Standards and Certifications | 
     
    
      | EMC | 
      CE, FCC | 
     
    
      | EMI | 
      EN 55022 Class B, FCC Part 15 Subpart B Class A | 
     
    
      | EMS | 
      EN 55024, 
        EN 61000-4-2 (ESD), 
        EN 61000-4-3 (RS), 
        EN 61000-4-4 (EFT), 
        EN 61000-4-5 (Surge), 
        EN 61000-4-6 (CS), 
        EN 61000-4-8, 
        EN 61000-4-11 | 
     
    
      | Green Product | 
      RoHS, CRoHS, WEEE | 
     
    
      | • Reliability | 
     
    
      | Automatic Reboot Trigger | 
      Built-in WDT (watchdog timer) | 
     
    
      | MTBF (mean time between failures) | 
      288,173 hrs | 
     
  
 
		 
		
	 
 
		 | 
   
 
 
											 |