| • Technology |
| Standards |
IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3x for Flow Control IEEE 802.1D-2004 for Spanning Tree Protocol IEEE 802.1w for Rapid STP IEEE 802.1Q for VLAN Tagging |
| • Software Features |
| Management |
IPv4/IPv6, SNMP v1/v2c/v3, LLDP, Port Mirror, DHCP Client, Syslog, SNMP Inform, Flow Control, Back Pressure Flow Control |
| Filter |
IEEE 802.1Q VLAN |
| Redundancy Protocols |
STP, RSTP |
| Security |
Broadcast Storm Protection, Port Lock, SNMPv3, HTTPS |
| Time Management |
SNTP/NTP Server/Client |
| Industrial Protocols |
EtherNet/IP, PROFINET IO, and Modbus/TCP |
| MIB |
RFC1213 MIB, Ether-Like MIB, IF MIB, LLDP-MIB, BRIDGE MIB, Q-BRIDGE MIB |
| • Switch Properties |
| Max. Number of VLANs |
8 |
| VLAN ID Range |
VID 1 to 4094 |
| MAC Table Size |
8 K |
| Packet Buffer Size |
3 Mbit |
| • Interface |
| RJ45 Ports |
10/100BaseT(X) auto negotiation speed |
| Storage Port |
USB storage (Type A connector for ABC-02-USB) |
| Alarm Contact |
1 relay output with current carrying capacity of 1 A @ 24 VDC |
| Digital Inputs |
1 input with the same ground, but electrically isolated from the electronics.• +13 to +30 V for state “1” • -30 to +3 V for state “0” • Max. input current: 8 mA |
| Button |
Reset button |
| • Power Requirements |
| Input Voltage |
12/24/48/-48 VDC, redundant dual inputs |
| Operating Voltage |
9.6 to 60 VDC |
| Input Current |
0.55 A @ 24 V |
| Overload Current Protection |
Supported |
| Connection |
2 removable 4-contact terminal blocks |
| Reverse Polarity Protection |
Supported |
| • Physical Characteristics |
| Housing |
Metal |
| IP Rating |
IP40 |
| Dimensions |
20 x 135 x 111 mm (0.79 x 5.32 x 4.37 in) |
| Weight |
438 g (0.97 lb) |
| Installation |
DIN-rail mounting |
| • Environmental Limits |
| Operating Temperature |
Standard Models: -10 to 60°C (14 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
| Storage Temperature |
-40 to 85°C (-40 to 185°F) |
| Ambient Relative Humidity |
5 to 95% (non-condensing) |
| • Standards and Certifications |
| Safety |
UL 61010-2-201, EN 60950-1 (Preliminary) |
| EMC |
EN 61000-6-2/6-4 |
| EMI |
CISPR 22, FCC Part 15B Class A |
| EMS |
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: Signal: 10 V IEC 61000-4-8 PFMF: 300A/m, 60 s |
| Shock |
IEC 60068-2-27 |
| Freefall |
IEC 60068-2-32 |
| Vibration |
IEC 60068-2-6 |
| Note |
Please check Moxa’s website for the most up-to-date certification status. |
| • MTBF (mean time between failures) |
| Time |
1,391,620 hours |
| Standard |
Telcordia (Bellcore), GB |