Moxa ABC-01-P-M12-CT-T - Configuration backup and restoration tool with M12 connector for ToughNet series EN50155 managed Ethern by MOXA
|
|
|
|
- Plug-n-Play system configuration backup and restoration
- Rugged design to enhance reliability
- Supports Moxa’s managed Ethernet switches and wireless APs/bridges/clients
- Designed to be continuously plugged in to Moxa’s managed Ethernet switches and wireless APs/bridges/clients
- Complies with all EN 50155 mandatory test items*
*This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here: www.moxa.com/doc/specs/EN_50155_Compliance.pdf
|
|
|
The ABC-01-P-M12-CT-T is designed for system backup and restoration to enhance maintenance efficiency and reduce system downtime in railway applications, including rolling stock and wayside installations. The ABC-01-P-M12 Automatic Backup Configurator tool can be used to save and load the configuration of Moxa’s ToughNet managed Ethernet switches and wireless APs/bridges/clients through the RS-232 console port. The ABC-01-P-M12 can be continuously plugged in to Moxa’s Ethernet switches and wireless APs/bridges/clients while the devices are operating, and makes it easier to back up system parameters and manage configurations. With the ABC-01-P-M12, you can quickly configure a replacement switch (of the same model).
The ABC-01-P-M12 is compliant with mandatory sections of EN 50155, covering operating temperature, surge, ESD, and vibration, as well as conformal coating, making the ABC-01-P-M12 suitable for a variety of industrial applications.
| • Interface |
| Connectors |
RS-232 M12 port |
| • Basic Operation |
| Storage Capacity |
64 KB |
| • Power Requirements |
| Input Voltage |
3 to 5 VDC, power input via RS-232 RTS |
| • Physical Characteristics |
| Housing |
Aluminum |
| IP Rating |
IP67 protection |
| Dimensions |
55 mm x Ø20 mm (2.17 in x Ø0.79 in) |
| Weight |
35 g (0.08 lb) |
| • Environmental Limits |
| Operating Temperature |
-40 to 75°C (-40 to 167°F) |
| Storage Temperature |
-40 to 85°C (-40 to 185°F) |
| Ambient Relative Humidity |
5 to 95 % (non-condensing) |
| Altitude |
2000 m |
| • Standards and Certifications |
| EMI |
CISPR 32, FCC Part 15B Class A |
| EMS |
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 20 V/m (80 MHz to 1 GHz)
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 |
| Rail Traffic |
(for plug in installations)
EN 50155*, EN 50121-4, EN 45545-2 |
| *This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here www.moxa.com/doc/specs/EN_50155_Compliance.pdf |
| Shock |
EN 50155, IEC 61373 |
| Freefall |
IEC 60068-2-31 |
| Vibration |
EN 50155, IEC 61373 |
| • MTBF (mean time between failures) |
| Time |
19,563,216 hrs |
| Standard |
Telcordia SR332 |
|
|