Power |
Input Supply Voltage |
6 - 30 vDC, unregulated ( 12 vDC Nominal ) |
Current |
175 mA |
Power Consumption |
2.1 watts |
Power Connector |
5.5mm x 9.5mm x 2.1mm barrel socket |
Power Adapter |
Universal AC/DC adapter |
100-240v AC, regulated DC adapter included |
Indicators |
Power / TST |
This green LED is turned on when power is applied to the media
converter. Otherwise it is off. The LED will blink when in Loopback test
mode. |
Fiber link on / Receive activity (LKF) |
This green LED is operational only when power is applied. The LED is on
when the 100Base-FX link is on and flashes with a 50% duty cycle when
data is received. |
Copper link on / Receive activity (LKC) |
This green LED is operational only when power is applied. The LED is on
when the 100Base-TX link is on and flashes with a 50% duty cycle when
data is received. |
Fiber Duplex (FDF) |
This green LED is operational only when power is applied. The LED is on
when the 100Base-FX link is operatinal in full duplex mode. The LED is
off when in half duplex. |
Copper Duplex (FDC) |
This green LED is operational only when power is applied. The LED is on
when the 10/100Base-TX link is operatinal in full duplex mode. The LED
is off when in half duplex. |
10/100 Speed |
This green LED is operational only when power is applied. The LED is on
when the speed of the copper Ethernet port is running at 100 MBPS. The
LED is off when in 10 MBPS |
Switches - accessible through a side opening in the chassis |
Auto-Negotiation (802.3u) |
Enabled (Default) -
The media converter uses 802.3u Auto-negotiation on the 100Base-TX
interface. It is set to advertise full duplex.
Disabled - The media
converter sets the port according to the position of the speed and
duplex switches. |
Link Pass Through |
Enabled (Default) -
When the state of the receiver is changed on the 100Base-TX interface it
is reflected on the 100Base-FX fiber transmitter. When the state of the
receiver on the 100Base-FX interface is changed it is reflected on the
100Base-TX transmitter.
When a Far-End Fault Indication is received on the fiber interface the
100Base-TX transmitter is turned off. When the Far-End Fault Indication
is cleared the transmitter is turned back on.
Disabled - The
100Base-TX and the 100Base-FX fiber interface operate independently.
Far-End Fault indication on the 100Base-FX fiber interface has no effect
on the 100Base-TX interface. |
Far-End Fault (FEF) |
Enabled (Default) -
The media converter transmits the Far-End Fault Indication over the
100Base-X fiber connection whenever a receive failure is detected on the
100Base-X fiber connection. The media converter continuously monitors
the100Base-X fiber connection and clears the Far-End Fault Indication
condition when a valid signal is received.
Disabled - Far-End
Fault Indications are not transmitted regardless of the condition of the
receive signal on the 100Base-FX fiber connection. |
Remote Loopback |
The media converter can perform a loopback on the 100Base-X fiber
interface.
Disabled (Default - Up)
Enabled - The
100Base-X receiver is looped to the 100Base-X transmitter. The
100Base-TX transmitter is taken off the interface. |
Auto-MDIX
(Internal Strap) |
If Auto-Negotiation (802.3u) is enabled, the media converter uses the HP
Auto-MDIX method for the 100Base-TX interface. If Auto-Negotiation
(802.3u) is disabled the Media converter will use the RX Energy method
on the 100Base-TX interface to set the port MDI or MDIX whichever is
appropriate.
Enabled (Default) -
Either a straight-through or crossover type cable can be used to connect
the media converter to the device on the other end of the cable.
Disabled - If the
partner device on the other end of the cable does not have the Auto-MDIX
feature a specific cable, either a straight-through or crossover will be
required to ensure that the media converter's transmitter and the
partner devices transmitter are connected to the others receiver. The
Media converter's 100Base-TX port is configured as MDI-X with this
switch setting. |
Speed Copper |
100 (Default)
10 |
Duplex Copper |
Full (Default)
Half |
Duplex Fiber |
Full (Default)
Half |
Connectors |
100Base-TX |
RJ45 connector, 2 pair CAT 5, EIA/TIA 568A/B or better cable |
Magnetic Isolation |
1.5kv |
Filtering |
Filtering |
1024 MAC Addresses |
Frame Specifications |
Buffer |
512 Kbits frame buffer memory |
Size |
Maximum frame size of 2048 bytes |
Environmental Specifications |
Operating Temperature |
0 C to 50 C (32 F to 122 F) |
Storage Temperature |
minimum range of -25 C to 70 C (-13 F to 158 F) |
Operating Humidity |
5% to 90% non-condensing |
Storage Humidity |
5% to 95% non-condensing |
Operating Altitude |
Up to 3,048 meters (10,000 feet) |
Heat Output
( BTU/HR ) |
7.2 |
MTBF (Hours)** |
Without power adaptor: 598,000
With power adaptor: 334,000 |
Mounting |
Din Rail Kit |
Optional |
Rack Mount Kit |
Optional |
Product Weight and Dimensions |
Weight |
0.3 kg, 0.66 lbs |
Dimentions |
120 x 80 x 26 mm, 4.7 x 3.1 x 1.0 inches |
Packaging |
Shipping Weight |
0.55 kg, 1.2 lbs |
Shipping Dimentions |
170 x 280 x 70 mm, 6.7 x 10.2 x 2.8 inches |
Regulatory Approvals |
Emissions |
FCC Part 15 Class B*, EN55022 Class B* |
CISPR 22 Class B* |
EN61000-3-2 |
Immunity |
EN55024 |
Electrical Safety |
UL 60950-1 |
EN60950 |
CE |
Laser Safety |
EN 60825-1:2007 |
Fiber optic transmitters on this device meet Class 1 Laser safety
requirements per IEC-60825 FDA/CDRH standards and comply with
21CFR1040.10 and 21CFR1040.11. |
Environmental |
Reach, RoHS and WEEE Compliant |
Other |
ECCN: 5A991A |
HTSUS Number: 8517.62.0050 |
Perle Limited Lifetime Warranty |
* When used with a Class B rated AC power adapter.