Ethernet |
eX-4S1110 |
Port |
4 port RJ45 – 10/100/1000 Base-T - Shielded |
Auto-MDIX |
Auto-MDIX enables proper operation with either straight-through or
crossover cabling |
Distance |
Distance up to 100 meters ( 328 feet ) as per IEEE 802.3 |
Maximum Frame Size |
1522 bytes |
VDSL – Interlink |
RJ45, BNC, Terminal Block |
TIP and RING are polarity insensitive. Surge suppresion of 400 volts
between TIP and RING Choice of RJ45, BNC or terminal block models for
VDSL link connector
- RJ45 – RING pin 4,
TIP pin 5 (TIA 568 A/B)
- BNC – Coaxial 75
ohm cable with BNC connector
- Terminal Block – 2
position screw connectors for use with twisted pair telephone
cabling
|
Cabling |
Ethernet Extenders must be connected in pairs using unconditioned wire
between 19 ( 0.9 mm ) and 26 AWG ( 0.44 mm ). Circuits that run through
signal equalization equipment are not permitted. |
VDSL2 Line Rate/Reach |
Actual distance and rates experienced will depend on condition and guage
of wire used. This Rate/Reach table applies to 24 AWG ( 0.5 MM ) twisted
pair wiring on RJ45 (RJ) and terminal block (TB) models.
High Speed Asymmetric |
Reach ( Distance ) |
VDSL Rate ( Mbps ) |
feet |
meters |
Downstream |
Upstream |
500 |
152 |
101 |
92 |
1000 |
305 |
101 |
63 |
1500 |
457 |
90 |
38 |
2000 |
610 |
62 |
24 |
2500 |
762 |
55 |
10 |
3000 |
914 |
42 |
5 |
3500 |
1000 |
35 |
3 |
High Speed Symmetric |
Reach ( Distance ) |
VDSL Rate ( Mbps ) |
feet |
meters |
Downstream |
Upstream |
500 |
152 |
101 |
101 |
1000 |
305 |
85 |
101 |
1500 |
457 |
62 |
47 |
2000 |
610 |
60 |
29 |
2500 |
762 |
44 |
14 |
3000 |
914 |
30 |
7 |
3500 |
1000 |
29 |
4 |
Long Reach Symmetric |
Reach ( Distance ) |
VDSL Rate ( Mbps ) |
feet |
meters |
Downstream |
Upstream |
500 |
152 |
53 |
44 |
1000 |
305 |
53 |
43 |
2500 |
762 |
39 |
18 |
4000 |
1219 |
25 |
4 |
5500 |
1676 |
17 |
1.9 |
7000 |
2134 |
8 |
2.3 |
7500 |
2286 |
7 |
2.2 |
8000 |
2438 |
5 |
2.2 |
Long Reach Asymmetric |
Reach ( Distance ) |
VDSL Rate ( Mbps ) |
feet |
meters |
Downstream |
Upstream |
500 |
152 |
78 |
16 |
1000 |
305 |
78 |
16 |
2500 |
762 |
55 |
10 |
4000 |
1219 |
31 |
0.8 |
5500 |
1676 |
20 |
0.6 |
7000 |
2134 |
11 |
0.6 |
7500 |
2286 |
10 |
0.6 |
8000 |
2438 |
8 |
0.6 |
|
Power |
eX-4S1110 |
Input Supply Voltage |
9 - 30 vDC, unregulated ( 12 vDC Nominal ) |
Current |
500 mA |
Power Consumption |
6 watts |
Power Connectors |
5.5mm x 9.5mm x 2.1mm barrel socket and 2 pin terminal Block |
Power Adapter |
Universal AC/DC adapter |
100-240v AC, regulated 12V DC adapter included |
Indicators |
Power / TST |
This green LED is turned on when power is applied to the Ethernet
Extender. Otherwise it is off. The LED will blink when in Loopback test
mode. |
CO - Local |
Ethernet Extender is operating in CO VDSL mode |
CPE - remote |
Ethernet Extender is operating in CPE VDSL mode |
ILNK |
Indicates Link Status and activity on the Interlink (VDSL) port |
ETH |
Indicates link status and activity on Ethernet port(s). |
Switches |
Access |
All switch settings are accessible through a side opening in the chassis |
Rate/Reach |
Two switches enable the user to select the right balance between speed
and distance for their environment. |
Signal to Noise Ratio |
Selectable Signal to Noise Ratio (SNR) of 6dB or 9dB. The higher SNR
number provides better impulse noise protection but lowers performance. |
Auto-Negotiation (802.3u) |
Enabled (Default) -
The Ethernet Extender uses 802.3u Auto-negotiation on the
10/100/1000Base-T interface. It is set to advertise full duplex.
Disabled - The
Ethernet Extender sets the port according to the position of the speed
and duplex switches. |
Loopback |
Enabled - The VDSL
interlink will perform a loopback function, retransmitting all received
Ethernet frames back to its peer.
Disabled (Default - Up) |
Set Ethernet Speed (Port 1) |
When Auto-Negotiation switch is disabled, fixed speed can be set at 100
(Default) or 10 |
Set Ethernet Duplex (Port 1) |
When Auto-Negotiation switch is disabled, Duplex can be set at Full
(Default) or Half |
Environmental Specifications |
Operating Temperature |
0 C to 50 C (32 F to 122 F) |
Storage Temperature |
minimum range of -25 C to 70 C (-13 F to 158 F) |
Operating Humidity |
5% to 90% non-condensing |
Storage Humidity |
5% to 95% non-condensing |
Operating Altitude |
Up to 3,048 meters (10,000 feet) |
Heat Output ( BTU/HR ) |
20.5 |
MTBF (Hours)** |
Without power adaptor: 365,542
With power adaptor: 207,212 |
Mounting |
Din Rail Kit |
Optional |
Rack Mount Kit |
Optional |
Product Weight and Dimensions |
Weight |
0.47 kg, 1.04 lbs |
Dimensions |
130 x 115 x 26 mm, 5.1 x 4.5 x 1.0 inches |
Packaging |
Shipping Weight |
0.75 kg, 1.7 lbs |
Shipping Dimensions |
170 x 260 x 70 mm, 6.7 x 10.2 x 2.8 inches |
Regulatory Approvals |
Emissions |
FCC Part 15 Class A, EN55022 Class A |
CISPR 22 Class A |
EN61000-3-2 |
Immunity |
EN55024 |
Electrical Safety |
UL 60950-1 |
EN60950 |
CE |
Environmental |
Reach, RoHS and WEEE Compliant |
Other |
ECCN: 5A991A |
HTSUS Number: 8517.62.0050 |
Perle Lifetime warranty |
*Available on 1 port models.
**Calculation model based on MIL-HDBK-217-FN2 @ 30 °C