IEX-402-SHDSL - Managed SHDSL Ethernet Extender with 1 10/100BaseT(X) port, and 1 DSL port, -10 to 60 Degree C operating temp by MOXA
|
|
|
- Automatic CO/CPE negotiation reduces configuration time
- Turbo mode connection, up to 15.3 Mbps over twisted-pair copper wires
- Link Fault Pass-through (LFP) support and interoperable with Turbo Ring and Turbo Chain
- Link quality indicators for simple troubleshooting
- Easy network management by web browser, Telnet/serial console, Windows utility, ABC-01, and MXview
|
|
|
The IEX-402 series is an industrial managed Ethernet extender designed with one 10/100BaseT(X) and one DSL port. The Ethernet extender provides a point-to-point extension over twisted copper wires based on G.SHDSL.bis and VDSL2 standards. The IEX-402-SHDSL supports data rates of up to 15.3 Mbps with a long transmission distance of up to 8 km, while the IEX-402-VDSL2 provides data rates of up to 100 Mbps with transmission distance of up to 3 km.
The IEX-402 series is designed for use in harsh operating environments. The DIN-rail mount, wide operating temperature range (-40 to 75°C), and dual power input make it ideal for installation in industrial applications.
To simplify configuration, the IEX-402 series uses CO/CPE auto negotiation. By factory default, the device will automatically assign CPE status to one of each pair of IEX devices. In addition, Link Fault Pass-through (LFP) and network redundancy interoperability enhance the reliability and accessibility of communication networks. Advanced managed and monitored functionality through MXview, including a virtual panel, improve the user experience for quick trouble shooting.
• Technology |
Standards |
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3x for Flow Control
IEEE 802.1p for Class of Service
ITU-T G.991.2 for Single-pair high-speed digital subscriber line transceivers |
Protocols |
SNMPv1/v2c/v3, DHCP Client, TFTP, SNTP, HTTP, Telnet, Syslog, LLDP, Modbus/TCP |
MIB |
MIB-II |
Flow Control |
IEEE 802.3x flow control, back pressure flow control |
• Switch Properties |
MAC Table Size |
1K |
Packet Buffer Size |
512K |
• Interface |
DSL Port |
DSL Port: RJ-11(RJ-45 connector) or detachable 2-contact terminal block |
RJ45 Ports |
10/100BaseT(X) auto negotiation speed, Full/Half duplex mode, and auto MDI/MDI-X connection |
Console Port |
RS-232 (RJ45 connector) |
DIP Switches |
CO/CPE, SNR/SPEED, ANNEX B/ANNEX A, STD/TURBO |
Button |
Reset button |
LED Indicators |
PWR1, PWR2, FAULT, STATE, LINK/ACT, CO/CPE, 10/100 (TP port) |
• Power Requirements |
Input Voltage |
12/24/48 VDC (9.6 to 60 VDC), redundant dual inputs |
Input Current |
0.36A @ 24 V |
Overload Current Protection |
Present |
Connection |
2 removable 2-contact terminal block |
Reverse Polarity Protection |
Present |
• Physical Characteristics |
Housing |
Metal, IP30 protection |
Dimensions |
35 x 130 x 105 mm (1.38 x 5.12 x 4.13 in) |
Weight |
290 g |
Installation |
DIN-rail mounting, wall mounting (with optional kit) |
Altitude |
Up to 2000 m |
Note |
Contact Moxa for products guaranteed to function at higher altitudes. |
• Environmental Limits |
Operating Temperature |
Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
• Standards and Certifications |
Safety |
UL 508 |
EMI |
FCC Part 15 Subpart B Class A, EN 55022 Class A |
EMS |
EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 3,
EN 61000-4-6 (CS) Level 3, EN 61000-4-8
Traffic Control: NEMA TS2 (IEX-402-VDSL2 only) |
Rail Traffic |
EN 50121-4 |
Shock |
IEC 60068-2-27 |
Freefall |
IEC 60068-2-32 |
Vibration |
IEC 60068-2-6 |
Note |
Please check Moxa’s website for the most up-to-date certification status. |
• MTBF (mean time between failures) |
Time |
1,310,000 hrs |
Database |
Telcordia (Bellcore), GB |
|
|