Need assistance or guidance?

Contact us @: 1-800-301-9097
Login / Register Contact Us
 
ME-10-T - 1 slot chassis, redundant power 12 to 48 VDC input. by MOXA

ME-10-T - 1 slot chassis, redundant power 12 to 48 VDC input.
by MOXA

Write a review Write a review
  •  1-slot chassis
  •  12 to 48 VDC power inputs
  •  2 10/100BaseT(X) Ports (RJ45 connector)
  •  2 power input
  •  Supported Overload Current Protection

 

Mfg SKU # : ME-10-T
Our Price : $117.97
Stock : Call for Availability
Quantity :
ME-10-T is a 1-slot chassis with redundant 12 to 48 VDC power inputs for The TRC-2190 Series which provides 18 slots for media converter modules from the CSM-400 Series of Ethernet-to-fiber management modules. It also supports SNMP/web console for remote management and monitoring. A TRC-2190 chassis comes with one AC or DC power input, with an optional redundant power expansion module available for greater reliability. The TRC-2190 Series’ power input module supports a fanless chassis design, as well as a -20 to 55°C operating temperature range.
Ethernet Interface
  • 10/100BaseT(X) Ports (RJ45 connector)

    • 2
Ethernet Software Features
  • Industrial Protocols

    • SNMPv1/v2c, SNMPv1/v2c Trap
  • Management

    • DHCP Client, IPv4/IPv6, SNMPv1/v2c, Syslog, TCP/IP, Telnet, TFTP, UDP, Web Console
  • MIB

    • MIB-II
  • Security

    • HTTPS/SSL, Local Account Accessibility, TACACS+, RADIUS, SSH
  • Time Management

    • NTP Client
Power Parameters
  • No. of Power Inputs

    • 2
  • Overload Current Protection

    • Supported
Physical Characteristics
  • IP Rating

    • IP30
  • Dimensions

    • 440 x 260 x 77 mm (18.6 x 11 x 3.3 in)
  • Weight

    • 5.2 g (11.4 lb)
  • Installation

    • 19-inch rack mounting
Environmental Limits
  • Operating Temperature

    • -20 to 55°C (-4 to 131°F)
  • Storage Temperature (package included)

    • -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity

    • 5 to 95% (non-condensing)
Standards and Certifications
  • EMC

    • EN 55032/24
  • EMI

    • CISPR 32, FCC Part 15B Class A
  • EMS

    • IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
      IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
      IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
      IEC 61000-4-5 Surge: Power: 1 kV; Signal: 0.5 kV
      IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
      IEC 61000-4-8 PFMF
  • Environmental Testing

    • IEC 60068-2-1
      IEC 60068-2-14
      IEC 60068-2-2
      IEC 60068-2-3
  • Safety

    • EN 60950-1, IEC 60950-1
  • Vibration

    • IEC 60068-2-6
MTBF
  • Time

    • 1,055,112 hrs
  • Standards

    • Telcordia (Bellcore), GB

Copyright © 2024 iComTech. All rights reserved. Shopping Cart Software powered by ecMidas.