PISO-CAN800U-D - 8-Port Isolated Protection Universal PCI CAN Card by ICP DAS
|
|
|
8-Port Isolated Protection Universal PCI CAN Communication Board. Includes One CA-4037W and Two CA-4002 Connectors, supports operating temperatures from 0 ~ 60 ℃
|
|
|
The CAN (Controller Area Network) is a serial communication protocol, and efficiently supports distributed real-time control with a very high level of security. It is an especially suit for networking "intelligent" devices as well as sensors and actuators within a system or sub-system. In CAN networks, there is no addressing of subscribers or stations in the conventional sense, but instead prioritized messages are transmitted. As standalone CAN controller, PISO-CAN800U-D can represent an economic solution of an active CAN board. It has eight independent CAN bus communication ports and has the ability to cover a wide range of CAN applications. Besides, PISO-CAN800U-D uses the new CAN controller Phillips SJA1000T and transceiver TJA1042, which provide bus arbitration, error detection with auto correction and re-transmission function. It can be installed in a 5V PCI slot and supported truly “Plug & play”.
Applications
- CAN bus communication application
- DeviceNet, CANopen, CAN J1939, SDS(System Wide Network) protocol application
- Control System
- Building Automation
- Factory Automation
- Distributed data acquisition
- One CAN bus communication port
- Compatible with CAN specification 2.0 parts A and B
- On-board optical isolation protection
- Programmable transfer rate up to 1 Mbps
- 2500 Vrms photo couple isolation on the CAN bus
- Jumper select 120Ω terminator resistor for each port
- Direct memory mapping to the CAN controllers
- 33MHz 32bit 5V PCI bus (V2.1) plug and play
Software Architecture
Utility
- Can be a CAN system monitor tool with CAN cards
- It is a good tool to test CAN system
- Send/Receive/Record CAN messages
- Provide cyclic transmission function
- Record the CAN messages with filtered ID and time stamp
- Support: 2000/XP/7
LabView Tool
In order to apply the PISO-CAN800U-D to CAN network with NI LabVIEW, we provides a LabVIEW 7/7.1 toolkit for the purpose. It is a useful tool to develop the CAN-relative application in NI LabVIEW environment by using PISO-CAN800U-D. It is easy to use and can help user to rapidly reduce their program development cycle. If users want to develop a LabVIEW industrial application with CAN network, the LabVIEW CAN driver is very helpful.
CAN LabVIEW Tool Features:
- Support extension arbitration id
- Support debug receive mode
- Start byte of output
- Support LabVIEW 7/7.1
- Scaling range to select
- Two languages, German and English
- Selectable data rates (baud): 10K, 20K, 50K, 125K, 250K, 500K, 800K, 1M, and user defined
Virtual CAN
There are various communication interfaces among the CAN devices like PCI CAN board, Ethernet series and RS-232 series CAN module. According to different purpose of users’ projects, the users maybe need to choice different CAN products. Because of this situation, the programmer should develop different communication program to handle different CAN device. For example, the user should develop “Socket Client” to communicate with I-7540. When using I-7530, the users need “UART” technique to communicate with it. Nowadays, ICP DAS develop the Virtual CAN technique. The Virtual CAN driver is the excellent tool for users. It transforms whole CAN devices into Virtual CAN port. And then it generates Virtual CAN port like “VxCAN 1” or “VxCAN 2”. The users could send and receive CAN message by appointing the Virtual CAN port number. The users don't need to care about what kind of CAN device which is used.
Indusoft Driver
InduSoft Web Studio is a powerful, integrated collection of automation tools that includes all the building blocks needed to develop modern Human Machine Interfaces (HMI), Supervisory Control and Data Acquisition (SCADA) systems, and embedded instrumentation and control application.
In order to apply the field bus communication by InduSoft software, ICP DAS provides several field bus components such as CAN, CANopen, DeviceNet and so on, in the InduSoft driver. By means of these drivers, you don't need to have the complex and abstruse background of these field bus protocols. Only few simple steps can finish the communication between your PC and the remote devices.
PC Platform |
File Select |
WinXP / Win7 |
InduSoft CAN Driver (IDCAN) for PC/XPAC-8000 (The InduSoft driver list ) |
Supported Devices |
CAN bus series |
I-7530, I-7530A, I-7540D, I-7565, I-7565-H1, I-7565-H2, PISO-CAN100U, PISO-CAN200U,PISO-CAN400U, PISO-CAN800U, PEX-CAN200i, PISO-CM100U |
CANopen series |
PISO-CPM100U, I-7565-CPM |
DeviceNet series |
PISO-DNM100U, I-7565-DNM |
PAC Platform |
File Select |
XPAC-8000 / XPAC-8000-Atom |
InduSoft CAN Driver (IDCAN) for PC/XPAC-8000
(The InduSoft driver list ) |
XPAC-8000-CE6 / XPAC-8000-Atom-CE6 |
InduSoft CAN Driver (IDCAN) for XPAC-8000-CE6
(The InduSoft driver list ) |
WinPAC / ViewPAC |
InduSoft CAN Driver (IDCAN) for WinPAC and ViewPAC
(The InduSoft driver list ) |
Supported Device |
CAN bus series |
I-8120W |
CANopen series |
I-8123W |
DeviceNet series |
I-8124W |
CANOpen Tools
In order to apply the CANopen protocol on the PISO-CAN800U-D easily, we provides two CANopen application Tools, which are CANopen library and CANopen diagnosis application tool. If users want to develop an industrial application with CANopen protocol, the CANopen library is very helpful to be applied with the PISO-CAN800U-D as the CANopen devices with the features of CANopen protocol. Besides, if the monitor and diagnosis of CANopen message on the CAN network is considered, the CANopen diagnostic application tool can be used to achieve this purpose.
CANopen Application Tool Features:
- Follow DS301 version 4.02
- Auto detecting CANopen slave devices
- IO monitor
- Dynamic PDO
- NMT master
- Support the Guarding and Heart beat protocol and SYNC message.
- Selectable data rates (baud): 10K, 20K, 50K, 125K, 250K, 500K, 800K, 1M
DeviceNet Tools
DeviceNet is a low level network that provides connections between simple industrial devices (sensors, actuators) and higher level devices (controllers). It allows direct peer to peer data exchange between nodes in an organized and, if necessary, deterministic manner. We provides DeviceNet library for users to develop the specific DeviceNet application by PISO-CAN800U-D. In addition, we also provide the DeviceNet diagnosis application tool to monitor and diagnose the DeviceNet message through CAN network. It provides the DeviceNet communication protocol interface to control and analysis the DeviceNet slaves.
DevcieNet Application Tool Features
- Auto detecting DeviceNet slave devices
- IO monitor
- Message monitor & diagnosis
- Support UCMM capable devices
- Support the Predefined Master/Slave connection set
- Selectable data rates (baud): 125K, 250K, 500K
DevcieNet Master X-Server Features
DeviceNet for LabVIEW Application Tool
In order to implement DeviceNet communication by NI LabVIEW software, ICPDAS provides a set of DeviceNet component for LabVIEW- “ICPDAS-DNET”. We also have the configuration utility to configure the ICPDAS’s DeviceNet hardware in your PC. The users not only operate easily and develop application rapidly, but also reduce the complexity of applications. The users can communicate with the remote DeviceNet devices in a few simple steps and need not to know about the detail of the DeviceNet protocol. It is a very useful tool to develop the DeviceNet application in NI LabVIEW environment by using ICPDAS-DNET. After finishing install the tool, we offer many basic and advance demo programs for users to reduce the development time. If you are new engineer to develop DeviceNet application, you can refer to the demo programs first. It is the best tool to develop various distributed systems and other industrial application software on DeviceNet network.
DevcieNet for LabVIEW software Features
Auto detecting DeviceNet slave devices
DeviceNet I/O monitor
Programmable MAC ID Setting
Provide hardware configuration tool
Support UCMM capable devices
Selectable data rates (baud): 125K, 250K, 500K Support the Predefined
Master/Slave connection set |
|
NI LabVIEW software Support
- NI LabVIEW Software V7.0 or newer
- NI-DNET DeviceNet driver V1.5 or newer
Performance Test
Platform:
OS:Windows XP SP 3
CPU:Intel(R) Core(TM) i3 CPU 550 @ 3.20GHz
RAM:1.8GB
The 1/2/4/8 CAN ports send, receive or send/receive 100,000 CAN messages at the same time. The average FPS values are shown below:
Baud rate (bps) |
1-CAN Port |
2-CAN Port |
2.0A, 8 bytes data |
2.0B, 8 bytes data |
2.0A, 8 bytes data |
2.0B, 8 bytes data |
TX (FPS) |
RX (FPS) |
TX/RX (Times/Sec) |
TX (FPS) |
RX (FPS) |
TX/RX (Times/Sec) |
TX (FPS) |
RX (FPS) |
TX/RX (Times/Sec) |
TX (FPS) |
RX (FPS) |
TX/RX (Times/Sec) |
10K |
88 |
88 |
43 |
73 |
73 |
37 |
44 |
88 |
43 |
37 |
73 |
37 |
20K |
176 |
176 |
87 |
146 |
146 |
75 |
88 |
176 |
87 |
73 |
146 |
75 |
50K |
440 |
441 |
218 |
365 |
367 |
188 |
218 |
441 |
213 |
181 |
367 |
184 |
125K |
1088 |
1104 |
537 |
899 |
917 |
461 |
523 |
1104 |
509 |
436 |
917 |
432 |
250K |
2100 |
2208 |
1025 |
1745 |
1834 |
882 |
984 |
2208 |
935 |
832 |
1834 |
804 |
500K |
3975 |
4414 |
1856 |
3305 |
3668 |
1612 |
1739 |
4414 |
1769 |
1528 |
3667 |
1492 |
800K |
5930 |
7008 |
2787 |
4950 |
5830 |
2355 |
2501 |
6701 |
2609 |
2096 |
5825 |
2226 |
1M |
7129 |
8722 |
3216 |
5926 |
7257 |
2820 |
2879 |
8716 |
3023 |
2506 |
7259 |
2650 |
Baud rate (bps) |
4-CAN Port |
8-CAN Port |
2.0A, 8 bytes data |
2.0B, 8 bytes data |
2.0A, 8 bytes data |
2.0B, 8 bytes data |
TX (FPS) |
RX (FPS) |
TX/RX (Times/Sec) |
TX (FPS) |
RX (FPS) |
TX/RX (Times/Sec) |
TX (FPS) |
RX (FPS) |
TX/RX (Times/Sec) |
TX (FPS) |
RX (FPS) |
TX/RX (Times/Sec) |
10K |
22 |
88 |
22 |
18 |
73 |
19 |
11 |
88 |
11 |
9 |
73 |
9 |
20K |
44 |
176 |
44 |
36 |
146 |
38 |
22 |
176 |
22 |
18 |
146 |
19 |
50K |
109 |
441 |
108 |
91 |
366 |
93 |
54 |
441 |
54 |
45 |
367 |
46 |
125K |
265 |
1103 |
257 |
221 |
916 |
222 |
132 |
1103 |
129 |
110 |
916 |
111 |
250K |
505 |
2205 |
492 |
424 |
1832 |
424 |
254 |
2205 |
243 |
221 |
1832 |
208 |
500K |
903 |
4409 |
917 |
782 |
3664 |
783 |
447 |
4408 |
435 |
385 |
3662 |
383 |
800K |
1365 |
7010 |
1317 |
1161 |
5546 |
1150 |
639 |
4905 |
637 |
553 |
3903 |
569 |
1M |
1598 |
8691 |
1541 |
1385 |
6901 |
1359 |
757 |
4903 |
795 |
658 |
3905 |
673 |
Bus Interface |
Type |
Universal PCI, 3.3 V and 5 V, 33 MHz, 32-bit, plug and play |
CAN Interface |
Controller |
NXP SJA1000T with 16 MHz clock |
Transceiver |
NXP TJA1042 |
Channel number |
8 |
Connector |
Female DB-37 |
Baud Rate (bps) |
10 k, 20 k, 50 k, 125 k, 250 k, 500 k, 800 k, 1 M (allow user-defined baud rate) |
Isolation |
3000 VDC for DC-to-DC, 2500 Vrms for photo-couple |
Terminator Resistor |
Jumper for 120 Ω terminator resistor |
Power |
Power Consumption |
800 mA @ 5 V |
Software |
Driver |
Windows 2K/XP/7, LabView, InduSoft |
Library |
VB 6.0, VC++ 6.0, BCB 6.0, Delphi 4.0, C#.Net, VB.Net |
Mechanism |
Dimensions |
193mm x 22mm x 93mm (W x L x H) |
Environment |
Operating Temp. |
0 ~ 60 ℃ |
Storage Temp. |
-20 ~ 70 ℃ |
Humidity |
5 ~ 85% RH, non-condensing |
|
|