SPL-24 - Industrial IEEE802.3af PoE splitter, Maximum output of 12.95W at 24 VDC, 0 to 60 Degree C by MOXA
|
|
|
- IEEE 802.3af compliant; splits power and data from PoE equipment
- Supports output power up to 12.95 W at 24 VDC
- Short circuit protection for power output
- -40 to 75°C operating temperature range (T model)
- DIN-rail mounting ability
|
|
|
With the technology of PoE, we can transfer both data and electrical power to Ethernet-enabled devices using a standard Ethernet CAT5 cable. SPL-24 plays the role of powered devices (PD) and splits power from PoEto Ethernet devices. In this case, both power and data can be transmitted up to 328 feet (100 m) from power source equipment (PSE).
This product can operate from 0 to 60°C or -40 to 75°C for T model, and the rugged hardware design makes SPL-24 perfect for ensuring your PoE Ethernet equipment can meet demanding industrial applications.
• Technology |
Standards |
IEEE 802.3af for Power-over-Ethernet IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) |
• Interface |
RJ45 Ports |
10/100BaseT(X) for PoE IN and DATA OUT |
LED Indicators |
Power |
• Power Requirements |
Input Voltage |
44 to 75 VDC (PoE) |
Output Voltage |
24 VDC |
Overload Current Protection |
400 mA @ 48 VDC input |
Connection |
1 removable 3-contact terminal block for output |
Output Power |
Max. 12.95 watts (0.54 A @ 24 VDC) |
• Physical Characteristics |
Housing |
Plastic, IP30 protection |
Dimensions |
24.9 × 100 × 86.2 mm (0.98 x 3.93 x 3.39 in) |
Weight |
95 g |
Installation |
DIN-rail mounting |
• Environmental Limits |
Operating Temperature |
Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
• Standards and Certifications |
Safety |
UL 69050-1 |
EMI |
FCC Part 15 Subpart B Class B, EN 55022 Class A |
EMS |
EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3, EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 3, EN 61000-4-6 (CS) Level 3, EN 61000-4-8 |
Marine |
DNV, GL, LR, ABS, NK |
Shock |
IEC 60068-2-27 |
Freefall |
IEC 60068-2-32 |
Vibration |
IEC 60068-2-6 |
Note |
Please check Moxa’s website for the most up-to-date certification status. |
• MTBF (mean time between failures) |
Time |
5,104,703 hrs |
Database |
MIL-HDBK-217F, GB 25°C |
|
|