PM-3133P - Modbus RTU Power Meter, Support Ethernet PoE Interface by ICP DAS

PM-3133P - Modbus RTU Power Meter, Support Ethernet PoE Interface
by ICP DAS

Write a review Write a review

Modbus RTU Power Meter. Supports Ethernet (PoE) interface with 12~48 VDC. DIN Rail Mountable and has operating temperatures of -10°C ~ +70°C (14°F ~ +158°F)

 

Mfg SKU # : PM-3133P
List Price : $369.00
Our Price : $362.00
Stock : Call for Availability
Quantity :
Aplication Image PM-3133-100ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3000 series that gives you access to real-time electric usage for three-phase power measurement. With its high accuracy (<0.5%, PF=1 ), the PM-3000 series can be applied to both low voltage primary side and/or medium/high voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipments in real time under operation. These compact size and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input current up to 300 A). It operates over a wide input voltages range 10 ~ 500 VAC which allows worldwide compatibility. And with 2 channels relay outputs, it can be linked with sirens or lightings for alarm messages. It also supports Modbus RTU for easy integration. You can use CT's that you currently own with PM-3133P (without CTs) Power Meter. The CT inputs of the PM-3133P can handle a maximum of 333mV of AC current.
Model PM-3133P
AC Power Measurement
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Measurement Voltage 10 ~ 500 V
Measurement Current Compatible with CTs from 50 to
2400A (333mV output)
Measurement Frequency 50/60 Hz
W Accuracy Better than 0.5% (PF=1)
Starting Current -
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh),
Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency (45 - 65Hz)
Data Update Rate 1 Second
Communication
Dimension Protocol Modbus-RTU
Baud rate 9600,19200 (default), 38400, 115200;􀀁DIP Switch Selectable
Data format N, 8, 1
Isolation 2500 VDC
Ethernet (PoE) Protocol -
CAN Bus Protocol -
Baud Rate -
Isolation -
Alarm Output
Power Relay Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC
Power
Power Input +12 ~ 48 VDC
Power Consumption 4 W
Dimensions (W x L x H) 127 mm x 105 mm x 33 mm
Mechanical
Casing Plastic
Dimensions (W x L x H) 127 mm x 105 mm x 33 mm
Operating Temperature -10°C ~ +70°C (+14°F ~ +158°F)
Storage Temperature -25 ~ +80 °C (-13° F ~ 176° F )
Environment
Operating Temperature -10 ~ +70 °C (14 °F ~ 158 °F)
Storage Temperature -25°C ~ +80°C (-13°F ~ +176°F )
Ambient Relative Humidity 10% ~ 90% RH, Non-condensing

Copyright © 2024 iComTech. All rights reserved. Shopping Cart Software powered by ecMidas.