29046228 QUINT4-PS/3AC/24DC/20 Power Supply - QUINT power supply with free choice of output characteristic curve, SFB (selective by PERLE

29046228 QUINT4-PS/3AC/24DC/20 Power Supply - QUINT power supply with free choice of output characteristic curve, SFB (selective
by PERLE

Write a review Write a review
  • Output Voltages: 24 or 48 V DC
  • Adjustable Output Voltage Ranges: 18 to 56 V DC
  • Output Amps: 10, 20 or 40 Amps
  • Output Watts: 240, 480 or 960 W
  • Will operate with 3-phase or 2-phase AC or DC input Voltage Ranges

 

Mfg SKU # : 29046228
List Price : $622.00
Our Price : $560.00
Stock : 5
Quantity :

29046228 QUINT4-PS/3AC/24DC/20 Power Supply of QUINT 3-Phase Power Supplies offer a range of rugged AC to DC and DC to DC Converters built to meet the high stability and efficiency expectations of industrial, machine automation and process control environments. They also feature the unique combination of preventive function monitoring and power reserve in an incredibly compact size. Perfect for use in high power applications, these Switching (switch mode) Power Supplies ensure a regulated output voltage even in the event of voltage fluctuations in the power supply network. During parallel operation, and when connected to different phases, loads are reliably supplied even in the event of problems with the input voltage. With all required safety certifications to support ITE (Information Technology Equipment), ruggedized packaging, extended operating temperatures, high peak load capabilities and high isolation voltages, QUINT Industrial Power Supplies are designed to meet the needs of your industrial application.

POWER BOOST: reliably start difficult loads

Power Boots Diagram

A high degree of flexibility is required to configure, optimize and expand large systems. To optimally adapt a system or machine to your requirements, a power reserve in the power supply unit is crucial. The QUINT supplies up to 50% additional current without a voltage drop. This is useful when it is not possible to predict which loads will be switched on at the same time or high switch-on currents of capacitive loads have to be absorbed without voltage dips. With the QUINT Power Boost function a static boost will continuously provide up to 125% of the nominal current. In addition, you can use the dynamic boost to supply up to 200% of the nominal current for 5 seconds when starting up heavy loads.

Preventive function monitoring reports critical operating states before they occur

Power Boots Diagram

With a QUINT Industrial Power Supply, the output voltage and output current are constantly monitored. Preventive function monitoring visualizes critical operating states and indicates them locally and remotely to the controller as follows:

  • Via LED
  • Via floating relay contact
  • Via active switching output

Industrial operating temperature of -25°C to +70°C

Equipment found in traffic management, oil and gas pipelines, weather tracking, industrial and outdoor applications must function in temperatures that cannot be supported by a commercial power supplies. With an operating temperature of -25°C to +70°C, and reliable device start-up at -40°C, the QUINT Industrial Power Supply is ideal for use with equipment subjected to harsh environments and severe temperatures.

High efficiency and low no load power consumption

Compared with other products on the market, the QUINT Industrial Power Supply provides excellent energy savings. With a very low no load power consumption and high efficiency at nominal load, just a small amount of electrical energy is converted into undesired heat energy making these very ECO friendly power supplies.

QUINT Industrial Power Supply Diagram

SFB (Selective Fuse Breaking) Technology

SFB Technology can be used to quickly and reliably trip miniature circuit breakers and fuses connected on the secondary side. In the event of a short circuit on the secondary side, the QUINT supplies up to 6 times the nominal current for 15 ms. Faulty current paths are switched off selectively, the fault is located, and important system parts remain in operation. Loads that are connected in parallel are still supplied with energy ensuring continued operation of these system parts.

  • Tripping circuit breakers: The circuit breaker is typically tripped by the high SFB current within 3 to 5 ms. As a result, any voltage dips for loads connected in parallel are avoided.
  • Tripping a fuse: Fuses are tripped by melting the predetermined breaking point inside the fuse capsule. The tripping characteristic of the fuse is described by the melting integral (I²t). A high current is crucial in order to achieve a very short tripping time.
NFC Image

Near Field Communication (NFC)

Near Field Communication (NFC) is a transmission standard for wireless and contactless data exchange at a close distance. With NFC, you can easily parameterize QUINT Power Supply settings such as define signaling thresholds for preventive function monitoring, adjust output voltage, and adapt the output characteristic curve to your specific requirements using a PC, mobile phone, or mobile terminal device. You can also save and send configuration profiles on your mobile terminal device. QUINT Power NFC App on the Google Play Store.

Ideal application environments for a QUINT 3-Phase Power Supply

  • Drive motors and other devices
  • Machine building
  • Automated production process
  • Industrial control, automation, assembly, and test equipment
  • Building control, security and surveillance, and climate control systems.
  • Power countless industrial automation devices such as sensors, controllers and valves

Other reasons to choose a QUINT 3-Phase Power Supply

  • Robust input side: high noise immunity, integrated gas-filled surge arrester (up to 6 kV), and ≥ 20 ms mains failure buffer time
  • Narrow, slim-line design saves space in the control box
  • Voltage Isolation input/output: 4 kV AC
  • Protections: Short-circuit, Overload, Over voltage, Over-temperature
  • High MTBF (Mean Time Between Failure) values
  23208278 28668028 29046218 29046228
Environmental Product Compliance
REACH SVHC Lead 7439-92-1 Lead 7439-92-1 Lead 7439-92-1 Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 25; Environmentally Friendly Use Period = 25; Environmentally Friendly Use Period = 25; Environmentally Friendly Use Period = 25;
General
Net weight 2.5 kg 2.5 kg 0.9 kg 1.1 kg
Efficiency > 93 % (at 400 V AC and nominal values) > 94 % (at 400 V AC and nominal values) typ. 93 % (400 V AC) typ. 93.9 % (400 V AC)
Insulation voltage input/output 4 kV AC (type test) 4 kV AC (type test) 4 kV AC (type test) 4 kV AC (type test)
2 kV AC (routine test) 2 kV AC (routine test) 2.4 kV AC (routine test) 2.4 kV AC (routine test)
Insulation voltage input / PE 3.5 kV AC (type test) 3.5 kV AC (type test) 3.5 kV AC (type test) 3.5 kV AC (type test)
2 kV AC (routine test) 2 kV AC (routine test) 2.4 kV AC (routine test) 2.4 kV AC (routine test)
Insulation voltage output / PE 500 V DC (routine test) 500 V DC (routine test) 0.5 kV DC (type test) 0.5 kV DC (type test)
Protection class I I I I
Degree of protection IP20 IP20 IP20 IP20
MTBF (IEC 61709, SN 29500) 889679,72 h (25 °C) > 880000 h (25 °C) > 1034000 h (25 °C) > 985000 h (25 °C)
501504,51 h (40 °C) > 500000 h (40 °C) > 654000 h (40 °C) > 638000 h (40 °C)
216825,67 h (60 °C) > 216000 s (60 °C) > 320000 h (60 °C) > 311000 h (60 °C)
Mounting position horizontal DIN rail NS 35, EN 60715 horizontal DIN rail NS 35, EN 60715 horizontal DIN rail NS 35, EN 60715 horizontal DIN rail NS 35, EN 60715
Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
Operating voltage display Green LED
Efficiency typ. 92.6 % (480 V AC) typ. 93.8 % (480 V AC)
Insulation voltage output / PE 0.5 kV DC (routine test) 0.5 kV DC (routine test)
Standards and Regulations
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Conformance with EMC Directive 2014/30/EU Conformance with EMC Directive 2014/30/EU Conformance with EMC Directive 2014/30/EU
Noise immunity EN 61000-6-2:2005 EN 61000-6-2:2005 Immunity according to EN 61000-6-1 (residential), EN 61000-6-2 (industrial), and EN 61000-6-5 (power station equipment zone), IEC/EN 61850-3 (energy supply) Immunity according to EN 61000-6-1 (residential), EN 61000-6-2 (industrial), and EN 61000-6-5 (power station equipment zone), IEC/EN 61850-3 (energy supply)
Connection in acc. with standard CSA CSA
Standards/regulations EN 61000-4-2 EN 61000-4-2 EN 61000-4-2 EN 61000-4-2
Contact discharge 4 kV (Test Level 2) 4 kV (Test Level 2) 4 kV (Test Level 2) 4 kV (Test Level 2)
Standards/regulations EN 61000-4-3 EN 61000-4-3 EN 61000-4-3 EN 61000-4-3
Frequency range 80 MHz ... 1 GHz 80 MHz ... 1 GHz 80 MHz ... 1 GHz 80 MHz ... 1 GHz
Test field strength 10 V/m (Test Level 3) 10 V/m (Test Level 3) 10 V/m (Test Level 3) 10 V/m (Test Level 3)
Frequency range 1.4 GHz ... 2 GHz 1.4 GHz ... 2 GHz 1.4 GHz ... 2 GHz 1.4 GHz ... 2 GHz
Test field strength 3 V/m (Test Level 2) 3 V/m (Test Level 2) 3 V/m (Test Level 2) 3 V/m (Test Level 2)
Standards/regulations EN 61000-4-4 EN 61000-4-4 EN 61000-4-4 EN 61000-4-4
Comments Criterion B Criterion B Criterion B Criterion B
Standards/regulations EN 61000-4-6 EN 61000-6-3 EN 61000-4-6 EN 61000-4-6
Frequency range 0.15 MHz ... 80 MHz 0.15 MHz ... 80 MHz 0.15 MHz ... 80 MHz 0.15 MHz ... 80 MHz
Voltage 10 V (Test Level 3) 10 V (Test Level 3) 10 V (Test Level 3) 10 V (Test Level 3)
Low Voltage Directive Conformance with LV directive 2006/95/EC Conformance with LV directive 2006/95/EC Conformance with Low Voltage Directive 2014/35/EC Conformance with Low Voltage Directive 2014/35/EC
Standard - Safety of transformers IEC 61558-2-17 EN 61558-2-16 (air clearances and creepage distances only) EN 61558-2-16 (air clearances and creepage distances only)
Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV) IEC 60950-1/VDE 0805 (SELV) IEC 60950-1/VDE 0805 (SELV) IEC 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV) EN 50178/VDE 0160 (PELV) / Overvoltage category III EN 50178/VDE 0160 (PELV) EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV) IEC 60950-1 (SELV) and EN 60204-1 (PELV) IEC 60950-1 (SELV) and EN 60204-1 (PELV) IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolation DIN VDE 0100-410 DIN VDE 0100-410 DIN VDE 0100-410 DIN VDE 0100-410
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment EN 50178
Standard – Limitation of mains harmonic currents EN 61000-3-2 EN 61000-3-2 EN 61000-3-2 EN 61000-3-2
Standard - Equipment safety BG (design tested) GS (tested safety)
Standard - Approval for medical use IEC 60601-1, 2 x MOOP
UL approvals UL Listed UL 508 UL Listed UL 508 UL Listed UL 508 UL Listed UL 508
UL/C-UL Recognized UL 60950-1 (3-wire + PE, star net) UL/C-UL Recognized UL 60950-1 (3-wire + PE, star net) UL/C-UL Recognized UL 60950-1 UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27) 18 ms, 30g, in each space direction (according to IEC 60068-2-27) 18 ms, 30g, in each space direction (according to IEC 60068-2-27) 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) 5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C) 5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C) 5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
15 Hz ... 150 Hz, 2.3g, 90 min.
Information technology equipment - safety (CB scheme) CB Scheme CB Scheme
Rail applications EN 50121-4 EN 50121-4 EN 50121-3-2 EN 50121-3-2
Overvoltage category (EN 62477-1) III III III (≤ 2000 m) III (≤ 2000 m)
Standards/regulations EN 61000-4-6 EN 61000-4-8 EN 61000-4-8
Standard - Safe isolation DIN VDE 0106-101
Shipbuilding approval DNV GL (EMC A), ABS, LR, RINA, NK, BV DNV GL, PRS, BV, LR, ABS DNV GL, PRS, BV, LR, ABS
Noise emission Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply) Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply)
Conducted noise emission EN 55016 EN 61000-6-4 (Class A) EN 55016 EN 61000-6-4 (Class A)
Standards/regulations EN 61000-4-11 EN 61000-4-11
EN 61000-4-9 EN 61000-4-9
EN 61000-4-12 EN 61000-4-12
EN 61000-4-16 EN 61000-4-16
EN 61000-4-18 EN 61000-4-18
Standard - power supply devices for low voltage with DC output EN 61204-3 EN 61204-3
EMC requirements, power plant IEC 61850-3
EN 61000-6-5
Approval - requirement of the semiconductor industry with regard to mains voltage dips SEMI F47-0706; EN 61000-4-11 SEMI F47-0706; EN 61000-4-11
Overvoltage category (EN 60950-1) II (≤ 5000 m) II (≤ 5000 m)
Overvoltage category (EN 61010-1) II (≤ 5000 m) II (≤ 5000 m)
Connection data, input
Connection method Screw connection Screw connection Screw connection Screw connection
Conductor cross section solid min. 0.2 mm² 0.2 mm² 0.2 mm² 0.2 mm²
Conductor cross section solid max. 6 mm² 6 mm² 6 mm² 6 mm²
Conductor cross section flexible min. 0.2 mm² 0.2 mm² 0.2 mm² 0.2 mm²
Conductor cross section flexible max. 4 mm² 4 mm² 4 mm² 4 mm²
Conductor cross section AWG min. 18 18 30 30
Conductor cross section AWG max. 10 10 10 10
Stripping length 7 mm 7 mm 8 mm 8 mm
Screw thread M3 M3
Output data
Nominal output voltage 48 V DC ±1 % 24 V DC ±1 % 24 V DC 24 V DC
Setting range of the output voltage (USet) 30 V DC ... 56 V DC (> 48 V DC, constant capacity restricted) 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted) 24 V DC ... 29.5 V DC (constant capacity) 24 V DC ... 29.5 V DC (constant capacity)
Nominal output current (IN) 20 A (-25 °C ... 60 °C, UOUT = 48 V DC) 40 A (-25 °C ... 60 °C, UOUT = 24 V DC) 10 A 20 A
POWER BOOST (IBoost) 22.5 A (-25°C ... 40°C permanent, UOUT = 48 V DC ) 45 A (-25°C ... 40°C permanent, UOUT = 24 V DC )
Selective Fuse Breaking (ISFB) 100 A (12 ms) 215 A (12 ms) 60 A (15 ms) 120 A (15 ms)
Derating 60 °C ... 70 °C (2.5%/K) 60 °C ... 70 °C (2.5%/K) > 60 °C (2.5%/K) > 60 °C (2.5%/K)
Connection in parallel Yes, for redundancy and increased capacity Yes, for redundancy and increased capacity Yes, for redundancy and increased capacity Yes, for redundancy and increased capacity
Connection in series yes yes yes yes
Feedback resistance max. 60 V DC max. 35 V DC ≤ 35 V DC ≤ 35 V DC
Protection against surge voltage on the output < 60 V DC < 35 V DC ≤ 32 V DC ≤ 32 V DC
Active current limitation Approx. IBOOST = 22.5 A (for short-circuit)
Control deviation < 1 % (change in load, static 10 % ... 90 %) < 1 % (change in load, static 10 % ... 90 %) < 0.5 % (Static load change 10 % ... 90 %) < 0.5 % (Static load change 10 % ... 90 %)
< 4 % (change in load, dynamic 10 % ... 90 %) < 3 % (change in load, dynamic 10 % ... 90 %) < 2 % (Dynamic load change 10 % ... 90 %, (10 Hz)) < 3 % (Dynamic load change 10 % ... 90 %, (10 Hz))
< 0.1 % (change in input voltage ±10 %) < 0.1 % (change in input voltage ±10 %) < 0.25 % (change in input voltage ±10 %) < 0.25 % (change in input voltage ±10 %)
Residual ripple < 50 mVPP (with nominal values) < 40 mVPP (with nominal values) < 75 mVPP (with nominal values) < 60 mVPP (with nominal values)
Output power 960 W 960 W 240 W 480 W
Typical response time < 1 s < 0.5 s 300 ms (from SLEEP MODE) 300 ms (from SLEEP MODE)
Maximum power dissipation in no-load condition 24 W 18 W < 5 W (400 V AC) < 7 W (400 V AC)
Power loss nominal load max. 70 W 63 W < 19 W (400 V AC) < 32 W (400 V AC)
Peak switching voltages nominal load < 5 mVPP (at nominal values, 20 MHz)
Static Boost (IStat.Boost) 12.5 A 25 A
Dynamic Boost (IDyn.Boost) 20 A (5 s) 30 A (5 s)
Maximum power dissipation in no-load condition < 5 W (480 V AC) < 7 W (480 V AC)
Power loss nominal load max. < 20 W (480 V AC) < 33 W (480 V AC)
Connection data for signaling
Conductor cross section solid min. 0.2 mm² 0.2 mm² 0.2 mm² 0.2 mm²
Conductor cross section solid max. 6 mm² 6 mm² 1.5 mm² 1.5 mm²
Conductor cross section flexible min. 0.2 mm² 0.2 mm² 0.2 mm² 0.2 mm²
Conductor cross section flexible max. 4 mm² 4 mm² 1.5 mm² 1.5 mm²
Conductor cross section AWG min. 18 18 24 24
Conductor cross section AWG max. 10 10 16 16
Screw thread M3 M3
Connection method Push-in connection Push-in connection
Stripping length 8 mm 8 mm
Dimensions
Width 96 mm 96 mm 50 mm 70 mm
Height 130 mm 130 mm 130 mm 130 mm
Depth 179 mm 176 mm 125 mm 125 mm
Width with alternative assembly 176 mm 176 mm 122 mm 122 mm
Height with alternative assembly 130 mm 130 mm 130 mm 130 mm
Depth with alternative assembly 99 mm 99 mm 53 mm 73 mm
Weight per piece 2500.0 GRM 2954.0 GRM 1000.0 GRM 1516.8 GRM
Input data
Nominal input voltage range 3x 400 V AC ... 500 V AC 3x 400 V AC ... 500 V AC 3x 400 V AC ... 500 V AC 3x 400 V AC ... 500 V AC
Input voltage range 3x 320 V AC ... 575 V AC 3x 320 V AC ... 575 V AC 3x 400 V AC ... 500 V AC -20 % ... +10 % 3x 400 V AC ... 500 V AC -20 % ... +10 %
2x 360 V AC ... 575 V AC (Not approved by UL) 2x 360 V AC ... 575 V AC 2x 400 V AC ... 500 V AC -10 % ... +10 % 2x 400 V AC ... 500 V AC -10 % ... +10 %
450 V DC ... 800 V DC 450 V DC ... 800 V DC ± 260 V DC ... 300 V DC -13 % ... +30 % ± 260 V DC ... 300 V DC -13 % ... +30 %
AC frequency range 45 Hz ... 65 Hz 45 Hz ... 65 Hz 50 Hz ... 60 Hz -10 % ... +10 % 50 Hz ... 60 Hz -10 % ... +10 %
Frequency range DC 0 Hz 0 Hz
Discharge current to PE < 3.5 mA < 3.5 mA < 3.5 mA < 3.5 mA
Current consumption 3x 2.1 A (400 V AC) 3x 2.1 A (400 V AC) 3x 0.5 A (400 V AC) 3x 0.99 A (400 V AC)
3x 1.7 A (500 V AC) 3x 1.7 A (500 V AC) 3x 0.41 A (480 V AC) 3x 0.81 A (480 V AC)
1.7 A (600 V DC) 1.7 A (600 V DC) 2x 1.1 A (400 V AC) 2x 1.62 A (400 V AC)
Nominal power consumption 1386 VA 1342 VA 274 VA 541 VA
Inrush surge current < 20 A (typical) < 15 A typ. 3 A (at 25 °C) typ. 2 A (at 25 °C)
Mains buffering typ. 25 ms (400 V AC) > 25 ms (400 V AC) typ. 29 ms (3x 400 V AC) typ. 33 ms (3x 400 V AC)
typ. 35 ms (500 V AC) > 35 ms (500 V AC) typ. 26 ms (3x 480 V AC) typ. 33 ms (3x 480 V AC)
Choice of suitable circuit breakers 6 A ... 16 A (AC: Characteristics B, C, D, K) 6 A ... 16 A (AC: Characteristics B, C, D, K) 3x 4 A ... 20 A (Characteristic B, C or comparable) 3x 4 A ... 20 A (Characteristic B, C or comparable)
Type of protection Transient surge protection Transient surge protection Transient surge protection Transient surge protection
Protective circuit/component Varistor Varistor, gas-filled surge arrester Varistor, gas-filled surge arrester Varistor, gas-filled surge arrester
Nominal input voltage range 2x 400 V AC ... 500 V AC 2x 400 V AC ... 500 V AC
± 260 V DC ... 300 V DC ± 260 V DC ... 300 V DC
Current consumption 2x 0.91 A (480 V AC) 2x 1.37 A (480 V AC)
3x 0.4 A (500 V AC) 3x 0.8 A (500 V AC)
2x 1.1 A (500 V AC) 2x 1.23 A (500 V AC)
Connection data, onput
Conductor cross section solid min. 0.2 mm² 0.2 mm² 0.2 mm² 0.2 mm²
Conductor cross section solid max. 6 mm² 6 mm² 1.5 mm² 1.5 mm²
Conductor cross section flexible min. 0.2 mm² 0.2 mm² 0.2 mm² 0.2 mm²
Conductor cross section flexible max. 4 mm² 4 mm² 1.5 mm² 1.5 mm²
Conductor cross section AWG min. 18 18 24 24
Conductor cross section AWG max. 10 10 16 16
Screw thread M3 M3
Connection method Push-in connection Push-in connection
Stripping length 8 mm 8 mm
Screw thread M3 M4
Ambient conditions
Degree of protection IP20 IP20 IP20 IP20
Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (start-up type tested) -40 °C -40 °C -40 °C -40 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C -40 °C ... 85 °C -40 °C ... 85 °C -40 °C ... 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing) ≤ 95 % (at 25 °C, non-condensing) ≤ 95 % (at 25 °C, non-condensing) ≤ 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721) 3K3 (in acc. with EN 60721) 3K3 (in acc. with EN 60721) 3K3 (in acc. with EN 60721)
Degree of pollution 2 2 2 2
Installation height 4000 m 4000 m ≤ 5000 m (> 2000 m, observe derating) ≤ 5000 m (> 2000 m, observe derating)
Approvals
 
  • ABS
  • DNV GL
  • BV
  • cCSAus
  • SEMI F47
  • RINA
  • cUL Recognized
  • cUL Listed
  • LR
  • UL Listed
  • IECEE CB Scheme
  • cULus Listed
  • UL Recognized
  • EAC
  • cULus Recognized
  • NK
  • CSA
  • Bauartgeprüft
  • CSAus