Need assistance or guidance?

Contact us @: 1-800-301-9097
Login / Register Contact Us
 
IEC-G102-BP-Pro-H - Industrial Intrusion Prevention System (IPS) device with 2 10/100/1000BaseT(X) ports, centralized management by MOXA

IEC-G102-BP-Pro-H - Industrial Intrusion Prevention System (IPS) device with 2 10/100/1000BaseT(X) ports, centralized management
by MOXA

Write a review Write a review
  •  Ultra-compact industrial security box with IPS/IDS
  •  Granular policy enforcement with whitelisting control
  •  LAN Bypass design to prevent a single point of failure and traffic overloading
  •  Bump-in-the-wire installation without impacting the network

 

Mfg SKU # : IEC-G102-BP-Pro-H
Our Price : $1,359.97
Stock : 2
Quantity :

The Moxa IEC-G102-BP-Pro-H industrial next-generation IPS devices protect mission-critical assets with industrial-grade IPS and whitelisting. Meanwhile, the Security Dashboard Console (SDC) software, when used together with the IEC-G102-BP Series, offers another layer of protection through centralized critical asset visibility, network analysis, and auto pattern updating.

Centrally Manage Network Security and Enhance OT Visibility

The IEC-G102–BP Series sniffers network traffic and gives users full visibility of current assets and connections, which helps administrators and operators understand the real-time conditions of the OT system. When connected to Security Dashboard Console, a security management platform, the administrators or operators can effectively manage and monitor all the intrusion prevention systems from a single space. This provides an easier way to monitor the devices and execute policy, firmware, and pattern updates.

Dynamically Prevent Malicious Cyber Threat Activity Affecting Your System

The IEC-G102–BP Series is designed to protect mission-critical assets at the OT network edge. It silently analyzes your network traffic in the background and offers granular behavior monitoring and control of cyber activities. These IPS devices provide both “Monitor” and “Protect” modes to facilitate different OT scenarios. Monitoring mode gives administrators full visibility of cyber threat activities. In the case of an emergency, administrators can easily switch to “Protect” mode to block and contain any malicious operations.

Industrial Protocol Whitelist Control for Mission-critical Assets

Using advanced Deep Packet Inspection (DPI) technology, the IEC-G102–BP Series is equipped with industrial protocol awareness to offer granular command of control system traffic to critical controllers.

Virtual Patching and Intelligent Threat Protection

Frequent patching significantly reduces a system’s vulnerability to cyberthreats. However, patching continues to be a major challenge in OT environments because OT applications cannot afford interrupting operations by shutting down systems to apply patches. Virtual patching technology can help complement existing patch management processes by shielding known and unknown vulnerabilities. Virtual patching acts as an agentless emergency security tool that OT administrators and operators can use to address vulnerabilities on affected OT equipment quickly. The IEC-G102–BP Series provides advanced protection against threats with up-to-date threat information and guards your systems against undisclosed and zero-day threats.

Flexible License Upgrades

The IEC-G102-BP Series supports flexible, on-demand expansion through Moxa’s license platform. As your network grows, you can purchase additional licenses based on your needs. The IEC-G102-BP Series supports the following licenses:

  • IEC-New-1Y: 1-year, 1 node IEC license

  • IEC-Renew-1Y: 1-year, 1 node IEC renewal license

  • IEC-Renew-2Y: 2-year, 1 node IEC renewal license

  • IEC-Renew-4Y: 4-year, 1 node IEC renewal license

  • SDC-New-1Y: 1-year, 1 node SDC license

  • SDC-New-3Y: 3-year, 1 node SDC license

  • SDC-New-5Y: 5-year, 1 node SDC license

  • SDC-Renew-1Y: 1-year, 1 node SDC renewal license

  • SDC-Add-4Q: 1-year, 1 node SDC add-on license

Input/Output Interface

  • Buttons

    Reset button

Ethernet Interface

  • 10/100/1000BaseT(X) Ports (RJ45 connector)

    2

  • Standards

    IEEE 802.3 for 10BaseT
    IEEE 802.3ab for 1000BaseT(X)
    IEEE 802.3u for 100BaseT(X)

LED Interface

  • LED Indicators

    PWR1, PWR2, MANAGED, IPS/IDS, USB/F, BYPASS, 10/100/1000M

DoS and DDoS Protection

  • Technology

    ICMP Flood, IGMP Flood, UDP Flood, TCP SYN Flood, TCP Port SYN Scan, TCP Port FIN Scan, TCP Port NULL Scan, TCP Port Xmas Scan, UDP Port Scan

Firewall

  • IPS Throughput

    > 200 Mbps

  • Latency

    < 500 microseconds

  • Deep Packet Inspection

    Modbus TCP
    Modbus UDP
    EtherNet/IP
    PROFINET-DCP
    CIP
    SLMP
    Omron FINS
    Siemens S7 Comm.
    Siemens S7 Comm. Plus
    Additional protocols will be supported through future firmware updates.

  • Policy Enforcement Rules

    64 rules

  • ICS Protocol Filter Profiles

    32 profiles

  • Concurrent Connections (TCP)

    10,0000

  • Automatic Pattern Updates via SDC

    Pro Models: Supported (1 year of updates included)
    Pro-H Models: Supported (requires IEC pattern update license)
    SA Models: Not supported

  • Manual Pattern Updates

    Pro Models: Supported (1 year of updates included)
    Pro-H Models: Supported (requires IEC pattern update license)
    SA Models: Supported (while under 5-year warranty)

Management

  • Supported Interfaces

    Web GUI and Security Dashboard Console

Real-Time Firewall / VPN Event Log

  • Event Type

    Cybersecurity, Policy enforcement, Protocol Filter, Assets detection, System event

  • Media

    Local storage, Syslog server

Serial Interface

  • Console Port

    USB Type-C

Power Parameters

  • Connection

    Removable terminal block

  • Input Current

    0.605 A @ 12 VDC, 0.297 A @ 24 VDC, 0.143 A @ 48 VDC

Physical Characteristics

  • Housing

    Metal

  • Dimensions

    40 x 70 x 83 mm (1.58 x 2.76 x 3.27 in)

  • Weight

    322 g (0.71 lb)

  • Installation

    DIN-rail mounting, Wall mounting (with optional kit)

Environmental Limits

  • Operating Temperature

    Standard Models: -10 to 60°C (14 to 140°F)
    Wide Temp. Models: -40 to 75°C (-40 to 167°F)

  • Storage Temperature

    -40 to 85°C (-40 to 185°F)

  • Ambient Relative Humidity

    5 to 95% (non-condensing)

Standards and Certifications

  • Safety

    UL 60950-1 Ed.2, UL 62368-1

  • EMC

    EN 55032/35

  • EMI

    CISPR 32, FCC Part 15B Class A

  • EMS

    IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
    IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
    IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 1 kV
    IEC 61000-4-6 CS: 3 V
    IEC 61000-4-8 PFMF

  • Hazardous Locations

    UL/cUL Class I Division 2 Groups A/B/C/D

  • Railway

    EN 50121-4

  • Traffic Control

    NEMA TS2

  • Shock

    IEC 60068-2-27

  • Freefall

    IEC 60068-2-32

  • Vibration

    IEC 60068-2-6

MTBF

  • Time

    1,340,000 hrs

  • Standards

    Telcordia (Bellcore), GB


Copyright © 2024 iComTech. All rights reserved. Shopping Cart Software powered by ecMidas.