• Data Line Surge Protection |
Maximum Power Protection |
5000 watts |
Number of Protected Lines |
4 |
Surge Capacity |
20 kV, 8/20 μs impulse per line |
Working Voltage |
1210-T: 15 V
1230-T: 5 V |
Maximum Load Current |
0.4 A (20°C), 0.13 A (85°C) |
Response Time |
< 1 ns |
Protection Mode |
Line to line, line to ground |
Protection Rating |
IP30 |
Bandwidth |
10 MHz loss < 1 dB |
• Connectors |
ISD-1210-T/1230-T |
Data in: Terminal block
Data out: Terminal block |
• Physical Characteristics |
Housing |
Metal |
Weight |
Product only
ISD-1210-T: 214 g
ISD-1230-T: 212 g
Packaged
ISD-1210-T: 276 g
ISD-1230-T: 274 g |
Dimensions |
ISD-1210-T: 95 x 53 x 25 mm (3.74 x 2.01 x 0.98 in)
ISD-1230-T: 95 x 53 x 25 mm (3.74 x 2.01 x 0.98 in) |
• Environmental Limits |
Operating Temperature |
-40 to 85°C (-40 to 185°F) |
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
95% max, non-condensing |
Altitude |
Up to 2000 m |
Note |
Please contact Moxa if you require products guaranteed to function properly at higher altitudes. |
• Standards and Certifications |
EMS |
IEC 61643-21 C2 (20 kV 1.2/50, 10 kA 8/20) |
• Warranty and RMA Policy |
Warranty Period |
5 years (limited to 1-time use) |
Note |
ISD products will only be repaired once within 5 years of purchase. After the first repair, the product’s warranty will no longer be valid. |
RMA Policy |
Moxa does not provide RMA service for ISD products whose PCB board was destroyed by a surge. |
Note |
Be sure to purchase the ISD product with maximum surge protection suitable for your environment. |