Need assistance or guidance?

Contact us @: 1-800-301-9097
Login / Register Contact Us
 
CP-602U-I w/o Cable - 2 Port CANbus Universal PCI Board, w/Isolation, 0 to 55  Degree C Temperature by MOXA

CP-602U-I w/o Cable - 2 Port CANbus Universal PCI Board, w/Isolation, 0 to 55 Degree C Temperature
by MOXA

Write a review Write a review
  • CAN 2.0A and CAN 2.0B supported
  • Two independent CAN communication ports
  • CAN transfer rate up to 1 Mbps
  • 2 kV electrical isolation
  • LED for transmit/receive status on each port
  • Optional 120 ohm terminal resistor for CAN bus network
  • DLL library and examples included
  • Windows driver provided
Mfg SKU # : CP-602U-I w/o Cable
Our Price : $451.54
Stock : Call for Availability
Quantity :
Moxa’s new CP-602U-I CAN (Controller Area Network) interface board supports the Universal PCI interface. As a stand-alone CAN controller, the CP-602U-I is a cost-effective solution that provides two active CAN controllers with a DB9 connector on the same board. The CP-602U-I CAN interface board uses the NXP SJA1000 and transceiver PCA82C251, which provide the bus arbitration and error detection. The -40 to 85°C wide operating temperature (CP-602U-I-T only) and 2 kV isolation make the boards suitable for use in harsh industrial environments.
 Hardware
Card Interface Universal PCI
Connectors DB9 male x 2
CAN Controller NXP SJA1000
CAN Transceiver PCA82C251
CAN Specification CAN 2.0 A/B
Signal Support CAN_H, CAN_L, GND
Transfer Rate 1 Mbps
Max. Number of Boards per PC 4
Electrical Isolation 2 kV
Termination Resistor 120 ohm (selected by jumper)
 Driver Support
Operating Systems Windows 2000, Windows XP/2003/Vista/2008 (x86/x64)
Linux Real TTY Drivers Linux 2.6.x, 3.x
Note Please refer to Moxa’s website for the latest driver support information.
 Software
Libraries Visual C/C++, Borland C/C++
 Environmental Limits
Operating Temperature Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Altitude Up to 2000 m
Note Please contact Moxa if you require products guaranteed to function properly at higher altitudes.
 Standards and Certifications
EMC CE, FCC
EMI EN 61000-3-2, EN 61000-3-3, FCC Part 15 Subpart B Class B
EMS IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 (DIPS)
Green Product RoHS, CRoHS, WEEE
 MTBF (mean time between failures)
Time 1,989,990 hrs
Database Telcordia (Bellcore), GB
 Power Requirements
Power Consumption 365 mA @ 5 VDC