CP-602U-I w/o Cable - 2 Port CANbus Universal PCI Board, w/Isolation, 0 to 55 Degree C Temperature by MOXA
|
|
|
- CAN 2.0A and CAN 2.0B supported
- Two independent CAN communication ports
- CAN transfer rate up to 1 Mbps
- 2 kV electrical isolation
- LED for transmit/receive status on each port
- Optional 120 ohm terminal resistor for CAN bus network
- DLL library and examples included
- Windows driver provided
|
|
|
Moxa’s new CP-602U-I CAN (Controller Area Network) interface board supports the Universal PCI interface. As a stand-alone CAN controller, the CP-602U-I is a cost-effective solution that provides two active CAN controllers with a DB9 connector on the same board. The CP-602U-I CAN interface board uses the NXP SJA1000 and transceiver PCA82C251, which provide the bus arbitration and error detection. The -40 to 85°C wide operating temperature (CP-602U-I-T only) and 2 kV isolation make the boards suitable for use in harsh industrial environments.
• Hardware |
Card Interface |
Universal PCI |
Connectors |
DB9 male x 2 |
CAN Controller |
NXP SJA1000 |
CAN Transceiver |
PCA82C251 |
CAN Specification |
CAN 2.0 A/B |
Signal Support |
CAN_H, CAN_L, GND |
Transfer Rate |
1 Mbps |
Max. Number of Boards per PC |
4 |
Electrical Isolation |
2 kV |
Termination Resistor |
120 ohm (selected by jumper) |
• Driver Support |
Operating Systems |
Windows 2000, Windows XP/2003/Vista/2008 (x86/x64) |
Linux Real TTY Drivers |
Linux 2.6.x, 3.x |
Note |
Please refer to Moxa’s website for the latest driver support information. |
• Software |
Libraries |
Visual C/C++, Borland C/C++ |
• Environmental Limits |
Operating Temperature |
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F) |
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
Altitude |
Up to 2000 m |
Note |
Please contact Moxa if you require products guaranteed to function properly at higher altitudes. |
• Standards and Certifications |
EMC |
CE, FCC |
EMI |
EN 61000-3-2, EN 61000-3-3, FCC Part 15 Subpart B Class B |
EMS |
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 (DIPS) |
Green Product |
RoHS, CRoHS, WEEE |
• MTBF (mean time between failures) |
Time |
1,989,990 hrs |
Database |
Telcordia (Bellcore), GB |
• Power Requirements |
Power Consumption |
365 mA @ 5 VDC |
|
|