Need assistance or guidance?

Contact us @: 1-800-301-9097
Login / Register Contact Us
 
PM-3114-240-MTCP - Modbus TCP, 4 Loops Single Phase Power Meter (200 A) by ICP DAS

PM-3114-240-MTCP - Modbus TCP, 4 Loops Single Phase Power Meter (200 A)
by ICP DAS

Write a review Write a review
  • True RMS Power Measurements
  • Energy Analysis for 1P2W, 1P4W
  • Current Measurements Up to 200 A with Different CT Ratio
  • Voltage Measurements Up to 300 V
  • Clip-on CT for Easy Installation
  • W Accuracy Better than 1% (PF=1)
  • Supports Ethernet Interface
  • Supports Modbus TCP Protocol
  • Supports 2 Power Relay Output (Form A)

 

Mfg SKU # : PM-3114-240-MTCP
List Price : $969.00
Our Price : $950.00
Stock : Call for Availability
Quantity :

PM-3114-240-MTCP is a Modbus TCP, 4 loops single-phase power meter, DIN Rail mount, supports input types: Vrms, Irms, kW, kWh, kVA, kVAh, kVAR, kVARh, PF, supports operating temperatures from -10 ~ +70°C (14°F ~ +158°F).

ICP DAS introduces powerful, cost-effective, advanced Smart Power Meters PM-3000 series that gives you access to real-time electric usage for single-phase power measurement. With its high accuracy (<1%, PF=1 ), the PM-3000 series can be applied to both low voltage primary side and/or medium/high voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipments in real time under operation. These compact size and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input current up to 200 A). It operates over a wide input voltages range 10 ~ 300 VAC which allows worldwide compatibility. And with 2 channels relay outputs, it can be linked with sirens or lightings for alarm messages. It also supports Modbus TCP protocol for easy integration.

AC Power Measurement
Wiring 1P4W-4CT
Input Voltage 10 ~ 300 V
Input Current CT Φ10 mm (60 A); CTΦ16 mm (100 A); CTΦ24 mm (200 A)
Input Frequency 50/60 Hz
W Accuracy Better than 1% (PF=1)
Starting Current >0.03A ( 60A ), >0.05A (100A ), >0.09A( 200A )
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)
Data Update Rate 1 Second
Communication
RS-485 Protocol -
Baud rate -
Data format -
Isolation -
Ethernet Protocol Modbus TCP
CAN Bus Protocol -
Baud rate -
Isolation -
Alarm Output
Power Relay Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC
Power
Input Range +12 ~ 48 VDC
Power Consumption 2 W
Mechanical
Casing Plastic (Flammability UL 94V-0)
Dimensions (W x L x H) 127 mm x 105 mm x 33 mm
Module Installation DIN-Rail Mounting
CT Installation Clip-On
Environment
Operating Temperature -10 ~ +70 °C
Storage Temperature -25 ~ +80 °C
Ambient Relative Humidity 10% ~ 90% RH, Non-condensing

Copyright © 2024 iComTech. All rights reserved. Shopping Cart Software powered by ecMidas.